This p a p er p resents im p roved measurin g method for measurement of the shielding effectiveness (SE) of small enclosures. The current standard IEEE 299 for determinin g shielding effectiveness is limited to the case of physically lar g e enclosures with dimensions over 2 m. New measuring method was verified in the anechoic chamber on small shieldin g box with dimensions 29 x 28 x 24 cm. Comparison between some measured values and results from the numerical model is shown at the end of the paper.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.