Hepatitis C virus remains a large health care burden to the world. Incidence rates across the world fluctuate and are difficult to calculate given the asymptomatic, often latent nature of the disease prior to clinical presentation. Prevalence rates across the world have changed as well with more countries aware of transfusion-related hepatitis C and more and more evidence supporting intravenous drug use as the leading risk factor of spread of the virus. This article reviews current hepatitis C virus prevalence and genotype data and examines the different risk factors associated with the virus.
TZP-102 for 28 days, at doses of 10-40 mg once daily, was well-tolerated and resulted in a reduction in symptoms of gastroparesis. The lack of correlation between symptom improvement and gastric emptying change is consistent with previous studies in diabetic gastroparesis, and emphasizes the value of patient-defined outcomes in determining therapeutic benefit.
AIMTo perform meta-analysis of the use of Endocuff during average risk screening colonoscopy.METHODSScopus, Cochrane databases, MEDLINE/PubMed, and CINAHL were searched in April 2016. Abstracts from Digestive Disease Week, United European Gastroenterology, and the American College of Gastroenterology meeting were also searched from 2004-2015. Studies comparing EC-assisted colonoscopy (EAC) to standard colonoscopy, for any indication, were included in the analysis. The analysis was conducted by using the Mantel-Haenszel or DerSimonian and Laird models with the odds ratio (OR) to assess adenoma detection, cecal intubation rate, and complications performed.RESULTSNine studies (n = 5624 patients) were included in the analysis. Compared to standard colonoscopy, procedures performed with EC had higher frequencies for adenoma (OR = 1.49, 95%CI: 1.23-1.80; P = 0.03), and sessile serrated adenomas detection (OR = 2.34 95%CI: 1.63-3.36; P < 0.001). There was no significant difference in cecal intubation rates between the EAC group and standard colonoscopy (OR = 1.26, 95%CI: 0.70-2.27, I2 = 0%; P = 0.44). EAC was associated with a higher risk of complications, most commonly being superficial mucosal injury without higher frequency for perforation.CONCLUSIONThe use of an EC on colonoscopy appears to improve pre-cancerous polyp detection without any difference in cecal intubation rates compared to standard colonoscopy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.