This paper deals with the experimental results obtained using different shapes of multi-port averaging device at different gauge pressure. The cross-section of the multiport averaging device is essential factor which effects the meter performance. A closed loop air test facility(CLATF) is used for testing and calibration of the flowmeter, which is used to measure the air flow rate or velocity of flow.The circular probe is a commercial design while the diamond shape with slight modification is analyzed for providing better performance and appreciable result with less disturbance in the flow line. The prototype test of the flowmeter is done at a defined length of upstream straight pipe after an elbow bend, for a condition of well defined turbulent flow profile. The calibration is done at 2 and 5 gauge pressure while the flow rate varied from 0.0283 to 0.1121m 3 /s. As a result, the diamond shaped probe with curved edges provided appreciable differential pressure and flow coefficient compared to circular probe keeping the same blockage to both the probe facing the flow.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.