Background
Nanoparticle albumin-bound paclitaxel (nab-PTX) is a promising antibody partner for anti-human epidermal growth factor receptor 2 (HER2). We performed neoadjuvant chemotherapy (NAC) for HER2-positive breast cancer (BC) using nab-PTX plus trastuzumab (T-mab) and pertuzumab (P-mab), followed by epirubicin and cyclophosphamide (EC).
Methods
In this multicenter phase II clinical trial (January 2019–July 2020), patients with stage I (T1c)-IIIB HER2-positive primary BC were treated with four cycles of nab-PTX plus T-mab and P-mab, followed by four cycles of EC. The primary endpoint was the pathological complete response (pCR) rate. Secondary endpoints were clinical response rate (RR), adverse events (AE), and tumor-infiltrating lymphocytes (TILs) in biopsy samples.
Results
In total, 43 patients were enrolled (mean age, 54 years). Twenty-two patients had HER2, and 21 patients had luminal/HER2-subtypes. The overall pCR rate was 53.5% (23/43, 95% CI: 42.6–64.1%, p = 0.184), whilst the pCR for HER2 was 68.2% (15/22, 95% CI: 45.1–86.1) and 38.1% for luminal/HER2 (8/21, 95% CI: 18.1–61.6%). The RR was 100% [clinical (c) CR:25, partial response (PR): 18]. AEs (≥ G3) included neutropenia (23.3%), leukopenia (7.0%), liver dysfunction (7.0%), and peripheral neuropathy (4.7%) when nab-PTX was administered. EC administration resulted in leukopenia (34.2%), neutropenia (31.6%), and febrile neutropenia (15.8%). The TILs in preoperative biopsy samples were significantly higher in pCR compared to non-pCR samples.
Conclusion
Nab-PTX plus T-mab and P-mab induced a high pCR rate in HER2-positive BC, particularly in the HER2-subtype. Given that AEs are acceptable, this regimen is safe and acceptable as NAC for HER2-positive BC.
Background: The GOD VISION wireless smart glass-shaped monitor (INBYTE) was used in the treatment of an elderly patient with mixed breathing disorder undergoing transanal minimally invasive surgery (TAMIS) for low rectal cancer under lumbar anesthesia. Method: After wearing the GOD VISION wireless smart glass-shaped monitor, we attached it to the Gel POINT Path® (Applied Medical). The tumor was surgically removed from all layers of the rectum using an ENDOPATH Electrosurgery PROBE PLUS II System® (a spatula-type electric scalpel) and the site was closed after sufficient washing. Results: The total operation time was 93 min, and the estimated blood loss was 6 mL. The patient was discharged without complications on postoperative day 14. No local recurrence or distant metastasis in the 7 months after the operation. The patient remained in a good condition with the preservation of the anal function. Conclusions: It is necessary to accumulate cases and to perform long-term follow-up. In addition, the anal side operators are able to operate without discomfort. In the present case, the GOD VISION wireless smart glass-shaped monitor allowed the TAMIS operation to be performed more comfortably.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.