In this paper, standard SS304 austenitic stainless steel and SS430 ferritic steel cylindrical rods were fabricated by friction welding process by varying the frictional pressure and forge pressure in order to understand the effect of process parameter. The tensile strength and Vickers micro hardness tests were conducted for each fabricated joint to evaluate the mechanical properties of the welded specimen. It was found that sample S5 with friction pressure of 90 MPa and forging Pressure of 120 MPa has the high tensile strength value of 637 MPa and 372HV at the interface region. A detailed microstructural analysis was performed at the interface to reveal interconnecting of dissimilar metals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.