Ribbed slabs have been widely used in buildings due to their many advantages, especially the decrease of concrete below the neutral line. This paper presents an experimental and computational study on ribbed slabs with wide-beam, two one-way slabs and two two-way slabs, with variable depths were tested to evaluate their resistance to punching and shear strength of slabs. Experimental and computational results showed that the wide-beam ribs connection is a critical point in the design of the slabs due to the difference in stiffness in the transition zone. Best results for the ultimate load estimates for ribs were provided by EC 2 (2004), while estimates of ACI 318 (2008) and NBR 6118 (2014) were respectively conservative and unsafe. Test results on slabs also revealed that the Brazilian alternative to analysis ribbed slabs as solid ones failed to give satisfactory results.
O manganês está entre os vinte elementos mais abundantes na crosta terrestre, é considerado essencial na fabricação do ferro e do aço, desoxidantes e na fabricação de ligas metálicas. Entretanto, durante a obtenção do manganês é gerado uma grande parcela de resíduo que vem sendo depositada em barragens. Aqui, esse resíduo foi avaliado como material fíler no cimento Portland. Os resultados mostraram que a substituição do cimento pelo resíduo aumenta a resistência à compressão e reduz os vazios e a absorção de água das amostras. Essas descobertas têm implicações importantes para substancial aplicação do resíduo como material suplementar ao cimento.
RESUMO: Avaliou-se a substituição da brita basáltica existente no concreto por material alternativo em abundância no município de Santarém-PA: a laterita. Foi avaliado o desempenho do concreto incorporado com agregado laterítico in natura em substituição parcial ao agregado graúdo de brita basáltica nos teores de 20% e 50%. Realizou-se a caracterização dos agregados graúdo e miúdo. De acordo com o método da ABCP, determinou-se o traço de referência em massa 1:1,71:3,03:0,53; confeccionou-se corpos-de-prova cilíndricos 10x20 cm utilizando 3 traços diferentes, de modo a substituir a brita basáltica pelo agregado laterítico, em 20% e 50%. Para cada traço foram quantificados a sua consistência, por meio do ensaio de abatimento do tronco de cone, resistência à compressão axial, resistência à tração por compressão diametral e módulo de elasticidade aos 28 dias. A substituição do agregado convencional de brita basáltica por agregado laterítico em seu estado natural promoveu diminuição da resistência a compressão simples, da resistência à tração por compressão diametral e do módulo de elasticidade com a inclusão do agregado laterítico na mistura. Destaca-se que acima de determinado teor de substituição o concreto torna-se inviável devido a necessidade de adicionar aditivo plastificante para manter a consistência desejada e que as duas misturas incorporadas com agregado laterítico se mostraram muito semelhantes após os 28 dias, no que tange a ganhos de resistência a compressão. ABSTRACT: This study is about the replacement of basaltic origin crushed stone by alternative material present in the municipality of Santarém, Pará State: the laterite. The aim were to evaluate the performance of concrete incorporated with natural lateritic aggregate, replacing the of crushed stone in 20% and 50%. The first stage was characterizing the coarse and fine aggregates that made up the studied concrete. According to ABCP dosing method it was determined the mass reference trait 1: 1.71: 3.03: 0.53; bodies of 10x20 cm were made for cylindrical test, using three different strokes so that the basaltic crushed stone gradually replaced by the lateritic aggregate in proportions of 20% and 50%. For each trait its consistency was quantified by means of the tapering test, axial compression strength, diametric compression tensile strength and the modulus of elasticity at 28 days. Was observed that the replacement of the conventional aggregate basalt crushed stone for aggregate of laterite in natural state promoted a decrease in the value of simple compressive strength, diametric tensile strength and modulus of elasticity with inclusion of a larger amount of lateritic aggregate in the mixture. It is noteworthy that above a certain substitution content, the concrete becomes not feasible due to the need for a large increase in the amount of plasticizer additive to the desired consistency is maintained and the two blends incorporated with lateritic showed very similar after 28 days in terms of gains in compressive strength.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.