This work presents on-wafer characterization measurements of the X-Hall current sensor architecture implemented in 90-nm BCD10 silicon process by STMicroelectronics. With respect to a previous implementation, technological improvements in terms of active region, isolation layers, and metal stack configuration result in a substantially improved sensitivity. In addition, it is reported that the sensitivity can be further improved by applying a negative voltage to the depletion layer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.