Background-There is a lack of information on the incidence and predictors of early mortality at 30 days and late mortality between 30 days and 1 year after transcatheter aortic valve implantation (TAVI) with the self-expanding CoreValve Revalving prosthesis. Methods and Results-A total of 663 consecutive patients (mean age 81.0Ϯ7.3 years) underwent TAVI with the third generation 18-Fr CoreValve device in 14 centers. Procedural success and intraprocedural mortality were 98% and 0.9%, respectively. The cumulative incidences of mortality were 5.4% at 30 days, 12.2% at 6 months, and 15.0% at 1 year.
Document covering atherosclerotic disease of extracranial carotid and vertebral, mesenteric, renal, upper and lower extremity arteries Endorsed by: the European Stroke Organization (ESO) The Task Force for the Diagnosis and Treatment of Peripheral Arterial Diseases of the European Society of Cardiology (ESC) and of the European Society for Vascular Surgery (ESVS)
While risk scores are invaluable tools for adapted preventive strategies, a significant gap exists between predicted and actual event rates. Additional tools to further stratify the risk of patients at an individual level are biomarkers. A surrogate endpoint is a biomarker that is intended as a substitute for a clinical endpoint. In order to be considered as a surrogate endpoint of cardiovascular events, a biomarker should satisfy several criteria, such as proof of concept, prospective validation, incremental value, clinical utility, clinical outcomes, cost-effectiveness, ease of use, methodological consensus, and reference values. We scrutinized the role of peripheral (i.e. not related to coronary circulation) noninvasive vascular biomarkers for primary and secondary cardiovascular disease prevention. Most of the biomarkers examined fit within the concept of early vascular aging. Biomarkers that fulfill most of the criteria and, therefore, are close to being considered a clinical surrogate endpoint are carotid ultrasonography, ankle-brachial index and carotid-femoral pulse wave velocity; biomarkers that fulfill some, but not all of the criteria are brachial ankle pulse wave velocity, central haemodynamics/wave reflections and C-reactive protein; biomarkers that do no not at present fulfill essential criteria are flow-mediated dilation, endothelial peripheral arterial tonometry, oxidized LDL and dysfunctional HDL. Nevertheless, it is still unclear whether a specific vascular biomarker is overly superior. A prospective study in which all vascular biomarkers are measured is still lacking. In selected cases, the combined assessment of more than one biomarker may be required.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.