This paper reports on a 7-year life table analysis on ITI titanium plasma-sprayed (TPS) and sandblasted and etched (SLA) implants placed in a private practice and loaded for at least 1 year. In 236 patients, 528 (264 TPS and 264 SLA) implants were placed, 351 (66.5%) implants rehabilitated the posterior region and 71.1% implants were < or =11 mm. In the posterior mandible and maxilla, the mean implant length was 9.90 and 9.74 mm respectively. Implant length was determined through standard radiographs only. Increase of the number of implants or reduction of the width or length of the rehabilitations was no specifically sought for the shorter implants. One hundred and twenty-two SLA implants were loaded within 63 days. All early loaded SLA implants resisted the applied 35 N cm without rotation or pain. Three implants failed, one early and two late failures, all were SLA implants placed in the mandible. Shorter implants did not fail more than longer ones. The cumulative success rate was 99.40%. The predictable use of short implants supporting single crowns and small fixed partial dentures of 2-4 units supported by two to three implants permitted (1) restricting the need for sophisticated and expensive presurgical procedures aimed to determine precisely the available bone height by computerized radiographic methods, (2) the placement of prosthetically driven restoration instead os surgically driven ones, (3) reducing the indications span for complex invasive procedures like sinus lift and bon grafting procedures, (4) facilitating the surgery, without attempting to place the longest implant and (5) avoiding the occurrence of sensation disturbance. The safe use of short implants in a private practice should make implant therapy simpler and accessible to a higher number of patients and practitioners.
Elevation of the sinus membrane alone without addition of bone grafting material can lead to bone formation beyond the original limits of the sinus floor. Despite a limited RBH at implant placement, a healing period of 3 months was sufficient to resist a torque of 35 N cm and to lead to a predictable implant function at the 1-year control.
Although more bone is gained when grafting material is used, this may not be required to promote endo-sinus bone gain. The OSFE procedure with or without grafting material could be efficient when the RBH is ≤ 4 mm. However, when both corticals merged, the risk of complication could increase.
This study confirms that the OSFE procedure without grafting material is sufficient to create bone beyond the natural limit of the sinus. On the mid-term of 3 years, the technique was found to be predictable in the posterior maxilla when the RBH is limited. Implants gained endo-sinus bone despite the lack of grafting material. Bone gain was still improving over the first-year control. No shrinkage of the augmented area was observed.
The purpose of the present clinical study was (1) to evaluate the Osstell as a diagnostic tool capable of differentiating between stable and mobile ITI implants, (2) to evaluate a cut-off threshold implant stability quotient (ISQ) value obtained at implant placement (ISQitv) that might be predictive of osseointegration, (3) to compare the predictive ISQitv of immediately loaded (IL) implants and implants loaded after 3 months (DL). Two patient groups were enrolled, 18 patients received 63 IL implants and 18 patients were treated with 43 DL implants. The ISQ was recorded at implant placement, after 1, 2, 4, 6, 8, 10 and 12 weeks. All implants passed the 1-year loading control. Two implants failed, one DL implant with ISQ at placement (ISQi) of 48 and one IL implant with ISQi of 53. The resonance-frequency analysis (RFA) method was not a reliable diagnostic tool to identify mobile implants. However, implant stability could be reliably determined for implants displaying an ISQ> or =47. After 1 year of loading, all DL implants with an ISQi> or =49 and all IL implants with an ISQi> or =54 achieved and maintained osseointegration. By the end of 3 months, implants with ISQi<60 had an increase of stability. Implants with ISQi 60-69 had their stability decrease during 8 weeks before returning to their initial values. Implants with ISQ>69 had their stability decrease during the first 4 weeks before remaining stable. Although preliminary, these data might orient the practitioner to choose among various loading protocols and to selectively monitor implants during the healing phase.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.