Inactivated influenza vaccine reduced proven influenza illness by 63% in infants up to 6 months of age and averted approximately a third of all febrile respiratory illnesses in mothers and young infants. Maternal influenza immunization is a strategy with substantial benefits for both mothers and infants. (ClinicalTrials.gov number, NCT00142389.)
BACKGROUND AND OBJECTIVE: Pneumonia is the leading cause of death of children. Diagnostic tools include chest radiography, but guidelines do not currently recommend the use of lung ultrasound (LUS) as a diagnostic method. We conducted a meta-analysis to summarize evidence on the diagnostic accuracy of LUS for childhood pneumonia. METHODS:We performed a systematic search in PubMed, Embase, the Cochrane Library, Scopus, Global Health, World Health Organization-Libraries, and Latin American and Caribbean Health Sciences Literature of studies comparing LUS diagnostic accuracy against a reference standard. We used a combination of controlled key words for age ,18 years, pneumonia, and ultrasound. We identified 1475 studies and selected 15 (1%) for further review. Eight studies (765 children) were retrieved for analysis, of which 6 (75%) were conducted in the general pediatric population and 2 (25%) in neonates. Eligible studies provided information to calculate sensitivity, specificity, and positive and negative likelihood ratios. Heterogeneity was assessed by using Q and I 2 statistics.RESULTS: Five studies (63%) reported using highly skilled sonographers. Overall methodologic quality was high, but heterogeneity was observed across studies. LUS had a sensitivity of 96% (95% confidence interval [CI]: 94%-97%) and specificity of 93% (95% CI: 90%-96%), and positive and negative likelihood ratios were 15.3 (95% CI: 6.6-35.3) and 0.06 (95% CI: 0.03-0.11), respectively. The area under the receiver operating characteristic curve was 0.98. Limitations included the following: most studies included in our analysis had a low number of patients, and the number of eligible studies was also small. Dr Pereda conceptualized and designed the study, reviewed all abstracts and selected articles to be included in the meta-analysis, was responsible for data collection, and drafted the initial manuscript; Dr Chavez conceptualized and designed the study, reviewed all abstracts and selected articles to be included in the meta-analysis, was responsible for data collection, led the analysis, and drafted the initial manuscript; Dr Hooper-Miele participated in analysis and interpretation of results, critically revised ultrasound methods used by selected studies, and reviewed and revised the manuscript; Drs Gilman, Steinhoff, Ellington, and Tielsch participated in the analysis and interpretation of results and reviewed and revised the manuscript; Ms Gross and Ms Price conducted the literature search and reviewed and revised the manuscript; Dr Checkley conceptualized and designed the study, contributed equally to the analysis, drafted the initial manuscript, and had ultimate oversight over the study conduct, analysis plan, and writing of the manuscript; and all authors approved the final manuscript as submitted and agree to be accountable for all aspects of the work.www.pediatrics.org/cgi
BackgroundGuidelines do not currently recommend the use of lung ultrasound (LUS) as an alternative to chest X-ray (CXR) or chest computerized tomography (CT) scan for the diagnosis of pneumonia. We conducted a meta-analysis to summarize existing evidence of the diagnostic accuracy of LUS for pneumonia in adults.MethodsWe conducted a systematic search of published studies comparing the diagnostic accuracy of LUS against a referent CXR or chest CT scan and/or clinical criteria for pneumonia in adults aged ≥18 years. Eligible studies were required to have a CXR and/or chest CT scan at the time of evaluation. We manually extracted descriptive and quantitative information from eligible studies, and calculated pooled sensitivity and specificity using the Mantel-Haenszel method and pooled positive and negative likelihood ratios (LR) using the DerSimonian-Laird method. We assessed for heterogeneity using the Q and I2 statistics.ResultsOur initial search strategy yielded 2726 articles, of which 45 (1.7%) were manually selected for review and 10 (0.4%) were eligible for analyses. These 10 studies provided a combined sample size of 1172 participants. Six studies enrolled adult patients who were either hospitalized or admitted to Emergency Departments with suspicion of pneumonia and 4 studies enrolled critically-ill adult patients. LUS was performed by highly-skilled sonographers in seven studies, by trained physicians in two, and one did not mention level of training. All studies were conducted in high-income settings. LUS took a maximum of 13 minutes to conduct. Nine studies used a 3.5-5 MHz micro-convex transducer and one used a 5–9 MHz convex probe. Pooled sensitivity and specificity for the diagnosis of pneumonia using LUS were 94% (95% CI, 92%-96%) and 96% (94%-97%), respectively; pooled positive and negative LRs were 16.8 (7.7-37.0) and 0.07 (0.05-0.10), respectively; and, the area-under-the-ROC curve was 0.99 (0.98-0.99).ConclusionsOur meta-analysis supports that LUS, when conducted by highly-skilled sonographers, performs well for the diagnosis of pneumonia. General practitioners and Emergency Medicine physicians should be encouraged to learn LUS since it appears to be an established diagnostic tool in the hands of experienced physicians.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.