Cetuximab can be safely administered with RT. The recommended dose for phase II/III studies is a loading dose of 400 to 500 mg/m(2) and a maintenance weekly dose of 250 mg/m(2).
Seven patients with lymphoma presenting as a breast mass are described. Four of them fulfilled the criteria for primary lymphoma of the breast, and three had evidence of secondary lymphoma of the breast. Two patients were diagnosed with stage IAE disease, and both did well with local treatment with or without chemotherapy. Two patients were diagnosed with stage IIAE disease; both had distant failure without systemic chemotherapy. Although local treatment is curative in a subset of stage IAE disease, combination chemotherapy followed by local radiation is a safer approach. For stage IIAE disease, combination chemotherapy and local radiation therapy should be considered.
Radiation doses delivered in high dose rate (HDR) brachytherapy are susceptible to many inaccuracies and errors, including imaging, planning and delivery. Consequently, the dose delivered to the patient may deviate substantially from the treatment plan. We investigated the feasibility of using TLD measurements in the urethra to estimate the discrepancy in treatments for prostate cancer. The dose response of the 1 mm diam, 6 mm long LiF rods that we used for the in vivo measurements was calibrated with the 192Ir HDR source, as well as a 60Co teletherapy unit. A train of 20 rods contained in a sterile plastic tube was inserted into the urethral (Foley) catheter for the duration of a treatment fraction, and the measured doses were compared to the treatment plan. Initial results from a total of seven treatments in four patients show good agreement between theory and experiment. Analysis of any one treatment showed agreement within 11.7% +/- 6.2% for the highest dose encountered in the central prostatic urethra, and within 10.4% +/- 4.4% for the mean dose. Taking the average over all seven treatments shows agreement within 1.7% for the maximum urethral dose, and within 1.5% for the mean urethral dose. Based on these initial findings it seems that planned prostate doses can be accurately reproduced in the clinic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.