In patients with neurofibromatosis type 1, transformation of neurofibromas into a malignant peripheral nerve sheath tumor (MPNST) is a severe complication of the disease. Fluorine-18-fluorodeoxyglucose PET/computed tomography (PET/CT) is a viable option for detecting malignant tumors in neurofibromatosis type 1 patients. The aim of this review was to assess the diagnostic performance of the most frequently used parameters of PET/CT in detecting MPNST. An extensive computer search was performed using the Cochrane Library, Pubmed, and Medline/Embase databases. Two reviewers independently extracted data of relevant studies and assessed the methodological quality (QUADAS-2). The diagnostic performance of PET/CT parameters in individual studies was determined by calculating a diagnostic odds ratio (DOR) using the absolute numbers of true-positive, true-negative, false-positive, and false-negative test results. A total of eight studies were included, of which three evaluated the standardized uptake value as a diagnostic parameter, two assessed the tumor-to-liver (T/L) ratio, and three articles described both parameters. The cut-off values for maximum standardized uptake value (SUVmax) ranged from 3.2 to 4.5; for the T/L ratio, the cut-off values were between 1.0 and 4.3. The sensitivity and specificity ranged from 90 to 100% and from 80 to 100%, respectively (SUVmax). T/L ratios were associated with 92-100% sensitivity and 72-94% specificity. The corresponding DORs ranged from 57 to 145 (SUVmax) and 35 to 655 (T/L ratio). Both the SUV and the T/L ratio are associated with high sensitivity combined with acceptable specificity in detecting MPNST. There is a tendency toward higher DORs using the T/L ratio, but the number of studies is limited.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.