Symptoms of Parkinson's disease (PD) progress despite optimized medical treatment. The present study investigated the effects of a flexibility and relaxation programme, walking, and Nordic walking (NW) on walking speed, stride length, stride length variability, Parkinson-specific disability (UPDRS), and health-related quality of life (PDQ 39). 90 PD patients were randomly allocated to the 3 treatment groups. Patients participated in a 6-month study with 3 exercise sessions per week, each lasting 70 min. Assessment after completion of the training showed that pain was reduced in all groups, and balance and health-related quality of life were improved. Furthermore, walking, and Nordic walking improved stride length, gait variability, maximal walking speed, exercise capacity at submaximal level, and PD disease-specific disability on the UPDRS in addition. Nordic walking was superior to the flexibility and relaxation programme and walking in improving postural stability, stride length, gait pattern and gait variability. No significant injuries occurred during the training. All patients of the Nordic walking group continued Nordic walking after completing the study.
Conditions were established for dispersing clay nanolayers into both cis-1,4-polyisoprene (synthetic) natural rubber (NR) and epoxidized natural rubbers (ENR) having 25 or 50 mol % epoxide. The clay was a sodium montmorillonite and was used as a pristine layered silicate or as organically modified layered silicates to make the galleries more hydrophobic and thus more compatible with the elastomers. The chemical modifications were carried out using an ion-exchange reaction with alkyl ammonium cations. Incorporation of the clays into the elastomers was achieved by mixing the components themselves in a standard internal blender or by mixing dispersions of them in toluene or methyl ethyl ketone. X-ray diffraction results indicated intercalation of NR and ENR into the silicate interlayers, followed by exfoliation of the silicate layers into the elastomer matrices. Of primary interest was the effect of the intercalated and exfoliated clays on the mechanical properties of the elastomers. The reinforcing effects obtained were found to depend strongly on the extent of the dispersion of the silicate layers into the rubber matrices.
ObjectCage subsidence occurs after anterior cervical discectomy and fusion (ACDF). The aim of this prospective study was to evaluate subsidence and total segmental height after implantation of a newly designed Wing titanium cage. Furthermore, alignment of the entire cervical spine was analyzed 2 years after surgery.MethodsFifty-four patients (26 women and 28 men) whose mean age was 48.3 years underwent ACDF. Follow-up examinations were performed at discharge and 6, 12, and 24 months postoperatively by an independent investigator. The clinical course was evaluated using the visual analog pain scale and the Prolo scales. Measurements of subsidence and total segmental height were conducted, and the alignment of the entire cervical spine was classified using two methods.In 54 patients 64 levels were fused. The patients noted a significant reduction of pain, and scores on both Prolo scales were significantly improved. At the 2-year follow-up examination, subsidence was present in 30 of the 67 fused segments. There was a statistically significant correlation between subsidence and the presence of posterior spondylosis at the initial surgery. Furthermore, there was a significant correlation between reduction of total segmental height and the presence of subsidence; however, subsidence did not prevent the development of a solid bone arthrodesis (fusion rate 98%) or have an adverse effect on the alignment of the cervical spine.ConclusionsTitanium Wing cage–augmented ACDF was associated with comparatively good long-term results. Subsidence was present but did not cause clinical complications. Furthermore, radiological studies demonstrated that the physiological alignment of the cervical spine was preserved and a solid bone arthrodesis was present at 2 years after surgery.
In our study the first clinical assessment of a new bone mounted robot system guiding percutaneous pedicle screw placement was done. A deviation <2 mm to the surgeon 's plan in 91.0% to 98.5% verifies the system's accuracy.
Articles you may be interested inQuantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging Rev. Sci. Instrum. 85, 103708 (2014); 10.1063/1.4898052 X-ray Talbot-Lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation AIP Conf.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.