Objectives Evaluate the effects of two different machined‐collar lengths and designs on peri‐implant healing. Material and Methods An implant with a microtextured surface and 3.6mm‐long internal‐connection machined collar was compared to two implants that had an identical 1.2mm‐long external‐connection machined collar, but one had the microtextured surface while the other's was machined. Participants received the three implants, with microgap at the crest, alternately at five sites between mental foramen, and a full‐arch prosthesis. Peri‐implant bone levels were measured after 23 to 26 years of function. Keratinized tissue height, plaque, probing depth, bleeding, and purulence were also evaluated. Descriptive and mixed models for repeated\measures analyses were used, with Bonferroni correction for pairwise comparisons. Results Twenty‐two participants (110 implants) were evaluated at the 25‐year examination. Microtextured implants with the longer machined collar had significantly greater mean marginal bone loss (−1.77mm ± 0.18, mean ± SE) than machined (−0.85mm ± 0.18, p < .001) and microtextured (−1.00 ± 0.18mm, p < .001) implants with the shorter machined collar. Keratinized tissue height was greater for internal‐connection (0.74mm ± 0.10) versus external‐connection (0.51 ± 0.08, p = 0.01) microtextured implants. No differences were observed for plaque (p = 0.78), probing depth (p = 0.42), bleeding (p = 0.07), and purulence (p = 1.00). Implant survival rate was 99%. Conclusions Implants with the 1.2mm machined collar limited bone loss to 1mm, while those with the longer machined collar showed > 1.5mm loss after 25 years of function with microgap at the crest. Internal‐connection design and fixture surface microtexturing did not result in greater bone preservation. ClinicalTrials.gov Identifier: NCT03862482.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.