Because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. Fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (ATs). In this study, the effect of maternal AT and depth in fetal dosimetry was investigated, using peripheral dose (PD) distribution evaluations. A BEAMnrc model of Oncor linac using out of beam components was used for dose calculations in out of field border. A 6 MV photon beam was used to irradiate a chest phantom. Measurements were done using EBT2 radiochromic film in a RW3 phantom as abdomen. The followings were measured for different ATs: Depth PD profiles at two distances from the field's edge, and in-plane PD profiles at two depths. The results of this study show that PD is depth dependent near the field's edge. The increase in AT does not change PD depth of maximum and its distribution as a function of distance from the field's edge. It is concluded that estimating the maximum fetal dose, using a flat phantom, i.e., without taking into account the AT, is possible. Furthermore, an in-plane profile measured at any depth can represent the dose variation as a function of distance. However, in order to estimate the maximum PD the depth of Dmax in out of field should be used for in-plane profile measurement.
Background: When using low-energy electron beams for the treatment of skin lesions, such as Mycosis Fungoides (MF), a beam spoiler is used to decrease electron therapeutic depth (R90) while increasing the surface dose.Objective: The aim of this study was to evaluate the characteristics of a 5 MeV electron beam when using a spoiler for the local treatment of MF skin lesions by Monte Carlo (MC) simulation.Methods: A Siemens Primus treatment head and an acrylic spoiler, positioned at the end of applicator, were simulated using BEAMnrc, an EGSnrc user code. The modelled beam was validated by measurement using MP3-M water tank, Roos parallel plate chamber and Semi flex Chamber-31013 (all from PTW, Freiburg, Germany). For different spoiler thicknesses, dose distributions in water were calculated for 2 field sizes and were compared to those for the corresponding open fields.Results: For a 1.3 cm spoiler, therapeutic range changed from 1.5 cm (open field) to 0.5 cm and 0.4 cm for 10 × 10 cm2 and 20 × 20 cm2 field sizes, respectively. Maximum increase in penumbra width was 2.8 and 3.8 cm for 10 × 10 cm2 and 20 × 20 cm2 field sizes, respectively. Maximum increase in bremsstrahlung contamination was %2 in both field sizes.Conclusion: R90 decreased exponentially with increase in spoiler thickness. The effect of field size on penumbra was much larger for spoiled beam compared to the open beam. The results of this research can be applied to optimize the radiation treatment of MF patients in our hospital.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.