Pericardial patch has been used to repair cardiac defects; however, its strength as an aortoplasty patch to tolerate systemic pressure is a matter of debate. We report an aneurysmal dilatation of pericardial patch in aortoplasty. Our patient was a 56-year-old female known case of rheumatic heart disease that underwent redoes mitral and aortic valve replacements along with Manouguian aortoplasty at the age of 44 years old. After 2 months, she was readmitted with a diagnosis of endocarditis. Echocardiography revealed a small cavity in the posterior wall of the aorta. She responded to medical therapy and discharged in a good condition. Twelve years later, she was scheduled to undergo reoperation due to a severe paraprosthetic aortic valve leakage and a pericardial patch aneurysm. The leaking prosthetic aortic valve was explanted and the aneurysmal tissue was replaced with a polyethylene terephthalate patch.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.