External-beam radiation therapy has been one of the treatment options for prostate cancer. The dose response has been observed for a dose range of 64.8-81 Gy. The problem of external-beam RT for prostate cancer is that as the dose increases, adverse effects also increase. Three-dimensional conformal radiation therapy (3D-CRT) has enabled us to treat patients with up to 72-76 Gy to the prostate, with a relatively acceptable risk of late rectal bleeding. Recently, intensity-modulated radiation therapy (IMRT) has been shown to deliver a higher dose to the target with acceptable low rates of rectal and bladder complications. The most important things to keep in mind when using an IMRT technique are that there is a significant trade-off between coverage of the target, avoidance of adjacent critical structures, and the inhomogeneity of the dose within the target. Lastly, even with IMRT, it should be kept in mind that a "perfect" plan that creates completely homogeneous coverage of the target volume and zero or small dose to the adjacent organs at risk is not always obtained. Participating in many treatment planning sessions and arranging the beams and beam weights create the best approach to the best IMRT plan.
We conducted a nationwide survey of multiple institutions and collected data of various interventional procedures in the field of cardiology. Included in the analysis were 126 institutions, 381 X-ray systems, and 805 protocols. The dose values were compared with the Japanese diagnostic reference levels (DRLs) 2015. Fluoroscopy time, air kerma at the patient entrance reference point (Ka, r), and air kerma-area product (PKA ) were analyzed for various interventional procedures in 5,734 cardiology patients. The fluoroscopic dose rate (FDR) for pulmonary vein isolation (PVI) was less than half that of the 75th percentile of the Japanese DRLs 2015. The 75th percentiles of fluoroscopy time, Ka, r, and PKA for the respective interventional procedures were as follows: 11.0 min, 735 mGy, and 64 Gy・cm 2 for diagnostic coronary angiography (CA); 13.2 min, 839 mGy, and 75 Gy・cm 2 for CA + left ventriculography; 34.4 min, 1,810 mGy, and 148 Gy・cm 2 for percutaneous coronary intervention (PCI) excluding chronic total occlusion; 80.1 min, 4,338 mGy, and 312 Gy・cm 2 for PCI for chronic total occlusion; 74.4 min, 833 mGy, and 90 Gy・cm 2 for PVI; and 34.0 min, 795 mGy, and 94 Gy・cm 2 for transcatheter aortic valve implantation, respectively. In assessing dose values in interventional radiology, the difficulty of the technique needs to be considered, and the DRL values for FDR, fluoroscopic time, Ka, r, and PKA for each interventional procedure are considered necessary when reassessing or updating DRLs.
In interventional radiology, dose estimation using the interventional reference point (IRP) is a practical method for obtaining the real-time skin dose of a patient. However, the IRP is defined in terms of adult cardiovascular radiology and is not suitable for dosimetry of the head. In the present study, we defined a new reference point (neuro-IRP) for neuro-interventional procedures. The neuro-IRP was located on the central ray of the X-ray beam, 9 cm from the isocenter, toward the focal spot. To verify whether the neuro-IRP was accurate in dose estimation, we compared calculated doses at the neuro-IRP and actual measured doses at the surface of the head phantom for various directions of the X-ray projection. The resulting calculated doses were fairly consistent with actual measured doses, with the error in this estimation within approximately 15%. These data suggest that dose estimation using the neuro-IRP for the head is valid.
It is important to optimize the exposure dose when conducting interventional radiology, but optimization is difficult for medical centers to achieve independently. In 2005, we administered a questionnaire on the measurement of dose rates and awareness of exposure reduction when performing percutaneous coronary intervention. Ten years later, we conducted a follow-up survey of the same 31 centers to determine the current situation and identify trends. The results of the survey showed that the mean fluoroscopy dose rate decreased to 55% of the 2005 value, from 28.2 to 15.6 mGy/min, and the mean radiography dose rate decreased to 71% of the 2005 value, from 4.2 to 3.0 mGy/s. Dose rates for both fluoroscopy and radiography decreased by 84% of facilities. The results also indicated greater cooperation by physicians compared to 10 years ago. In particular, there was a considerable increase in the exchange of ideas with physicians regarding exposure, suggesting a stronger level of interest in exposure. The overall score for questionnaire items was 33% higher than that in the previous survey. These results show that in the past 10 years, awareness of exposure reduction has improved, and dose optimization has been a major factor in the downward trend in dose rates in radiography and fluoroscopy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.