This study evaluated the effects of three types of hybrid iterative reconstruction (IR) on image quality of pediatric body computed tomography images. The image quality components evaluated were noise power spectrum (NPS), task-based modulation transfer function (TTF), and system performance function (SPF). As the IR strength was increased while reducing the radiation dose, the NPS increased in a low-frequency range and the TTF decreased in low-contrast regions. In the low-contrast regions, the calculated SPF decreased over the entire frequency range. Alternatively, in the high-contrast regions, the SPF decreased in the low-frequency regions and increased in the high-frequency regions. The radiation dose reduction using the hybrid IR resulted in the deterioration of the image quality in the low-contrast regions and changes in the spatial frequency characteristics in the high-contrast regions.
Purpose
Tolvaptan is the first approved treatment for autosomal dominant polycystic kidney disease (ADPKD) that targets a mechanism directly contributing to the development and growth of renal cysts. We investigated the ability of ultrasonography to predict total kidney volume (TKV) of 750 mL or more, which is an indication for tolvaptan therapy in patients with ADPKD.
Methods
A total of 46 patients with ADPKD were evaluated. The most statistically appropriate measurement based on ultrasonography for predicting TKV determined by computed tomography (CT) was assessed.
Results
TKV determined by CT was 796.8 (508.8–1,560.3) mL. The median length, anteroposterior distance, and mediolateral distance determined using ultrasonography were 15.7 cm, 7.6 cm, and 7.6 cm in the left kidney, and 13.4 cm, 6.9 cm, and 7.2 cm in the right kidney, respectively. Multivariate regression analysis showed that total kidney length (left and right) [variance inflation factor (VIF), 9.349] and total mediolateral distance (left and right) (VIF, 3.988) were independently associated with TKV. The correlation (r) between the logarithm of TKV determined by CT and total mediolateral distance determined using ultrasonography was 0.915 (p < 0.001). The linear regression equation was log (total kidney volume) = 1.833 + 0.075 × total mediolateral distance (left and right) based on ultrasonography. The area under the receiver operating characteristic curve for total mediolateral distance determined using ultrasonography to predict TKV of 750 mL or more was 0.989. Using the total mediolateral distance cut-off value of 14.2 cm, the sensitivity and specificity were 96.0% and 100.0%, respectively.
Conclusion
Total mediolateral distance determined using ultrasonography can predict TKV in patients with ADPKD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.