The 0.05 mmol/kg gadobenate dimeglumine-enhanced abdominal MRI studies at 3T and 1.5T MR systems are superior in relative enhancement of the liver in HADP to 0.025 mmol/kg gadoxetic acid-enhanced MRI. This type of assessment may provide comparative effectiveness data.
Our study describes % enhancement of liver and pancreas using various GBCAs. The data may provide reference material on relaxation properties of GBCAs in vivo.
Abstractobjective To describe magnetic resonance imaging (MRI) findings in musculoskeletal paracoccidioidomycosis (PCM).methods Retrospective case series study after IRB approval. Two musculoskeletal radiologists reviewed in consensus the MRI findings of 11 patients with microbiologically and/or pathologically proven osteoarticular PCM. The MRI evaluation included discrimination of abnormalities in joints, bones and soft tissues.
Objective: To evaluate the degree of similarity between manual and semiautomatic segmentation of soft-tissue sarcomas on magnetic resonance imaging (MRI). Materials and Methods: This was a retrospective study of 15 MRI examinations of patients with histopathologically confirmed soft-tissue sarcomas acquired before therapeutic intervention. Manual and semiautomatic segmentations were performed by three radiologists, working independently, using the software 3D Slicer. The Dice similarity coefficient (DSC) and the Hausdorff distance were calculated in order to evaluate the similarity between manual and semiautomatic segmentation. To compare the two modalities in terms of the tumor volumes obtained, we also calculated descriptive statistics and intraclass correlation coefficients (ICCs). Results: In the comparison between manual and semiautomatic segmentation, the DSC values ranged from 0.871 to 0.973. The comparison of the volumes segmented by the two modalities resulted in ICCs between 0.9927 and 0.9990. The DSC values ranged from 0.849 to 0.979 for intraobserver variability and from 0.741 to 0.972 for interobserver variability. There was no significant difference between the semiautomatic and manual modalities in terms of the segmentation times (p > 0.05). Conclusion: There appears to be a high degree of similarity between manual and semiautomatic segmentation, with no significant difference between the two modalities in terms of the time required for segmentation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.