Additional information:Use policyThe full-text may be used and/or reproduced, and given to third parties in any format or medium, without prior permission or charge, for personal research or study, educational, or not-for-prot purposes provided that:• a full bibliographic reference is made to the original source • a link is made to the metadata record in DRO • the full-text is not changed in any way The full-text must not be sold in any format or medium without the formal permission of the copyright holders.Please consult the full DRO policy for further details. Abstract We obtain the linear instability and nonlinear stability thresholds for a problem of thermal convection in a bidispersive porous medium with a single temperature. It is important to note that we show that the linear instability threshold is the same as the nonlinear stability one. This means that the linear theory is capturing completely the physics of the onset of thermal convection. This result contrasts with the general theory of thermal convection in a bidispersive porous material where the temperatures in the macropores and micropores are allowed be different. In that case the coincidence of the stability boundaries has not been proved.
Introduction. Milligan-Morgan haemorrhoidectomy performed with LigaSure system (LS) seems to be mainly effective where a large tissue demolition is required. This randomized study is designed to compare LigaSure haemorrohidectomy with conventional diathermy (CD) for treatment of IV-degree haemorrhoids. Methods. 52 patients with IV-degree haemorrhoids were randomized to two groups (conventional diathermy
versus LigaSure haemorrhoidectomy). They were evaluated on the basis of the following main outcomes: mean operative time, postoperative pain, day of discharge, early and late complications. The time of recovery of work was also assessed. All patients had a minimum follow-up of twelve months (range 12–24). All data were statistically evaluated. Results. 27 patients were treated by conventional diathermy, 25 by LigaSure. The mean operative time was significantly shorter in LS, such as postoperative pain, mainly lower on the third and fourth postoperative day: moreover pain disappeared earlier in LS than CD. The time off-work was shorter in LS, while there was no difference in hospital stay and overall complications rate. Conclusions. LigaSure is an effective instrument when a large tissue demolition is required. This study supports its use as treatment of choice for IV degree haemorrhoids, even if the procedure is more expansive than conventional operation.
According to our data, low-volume PEG+Asc has comparable efficacy, safety, and tolerability as high-volume PEG+Sim; therefore, it can be considered as a good alternative solution for bowel preparation. More improvements are necessary to achieve the target of a perfect preparation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.