Background:The outcome of the radiotherapy is highly dependent on how precisely dose is delivered to the tumor and should not exceed±5% of the prescribed dose including all types of uncertainties involved in the treatment procedure. Objectives: This manuscript describes the comprehensive Quality Assurance (QA) program for two linear accelerators by ensuring Percentage Depth Dose (PDD), Quality Index (QI), Beam Flatness and Symmetry, and beam output consistency at Khwaja Yunus Ali Medical College and Hospital, Sirajganj, Bangladesh. The program is designed according to the policy of the center and by the guidelines of Bangladesh Atomic Energy Regulatory Authority. Materials and Methods: The adopted QA procedure at our centre included daily, weekly, monthly, and yearly checks, as well as individual treatment verifications and participation in IAEA/WHO TLD inter-comparison Program. Results: The results of the study showed reproducibility in all QA procedures with an average photon for monthly beam output 0.988±0.011, 0.989±0.010 and 1.005±0.006 for 4 MV, 6 MV and 15 MV respectively. The maximum variation of calibration factors of the chambers for last five years between the manufacturer values and the average calibration coefficient lies within -0.298 to 0.47% with an uncertainty of ±1.8% (k=1). The results of IAEA/WHO TLD inter-comparison program of dose measurement shows the ratio of IAEA to KYAMCH values was 1.009±0.018. Conclusion: The above result shows an excellent agreement of calibration coefficient of ionization chambers and dosimetry with the international standard system.
Aims & Objectives: This study aimed to investigate the complications related to uro-genital system of patients who received radiotherapy for invasive cervical cancer. The patient selection is randomized who were evaluated in OPD Obst. Gynae. Deptt.of KYAMCH after receiving their full course of radiotherapy.100 patients were evaluated. In this study most of the women were perimenopausal, having 2-5 children, most of them were presented with vaginal discharge & postcoital bleeding, most of them received surgical treatment followed by radiotherapy & chemotherapy. During radiotherapy most of them having no complains, some of them were suffering from frequency of micturation & dysuria. 31% patient suffered from dyspareunia, 17% vaginal stenosis, 7% vaginal discharge and 7% cystitis. KYAMC Journal Vol. 3, No.-2, January 2013, Page 273-276 DOI: http://dx.doi.org/10.3329/kyamcj.v3i2.15166
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.