Recent data have shown that a temporary release in the transmembrane pressure can cause a significant increase in virus transmission through a number of commercial virus filters. The objective of this work was to study the effect of a pressure release on retention of the bacteriophage ΦX174 by the Ultipor DV20 membrane, with phage capture within the membrane visualized by confocal microscopy. Phage challenge tests showed a significant transient increase in phage transmission (typically by an order of magnitude) immediately after a pressure release. This transient increase was not due to any damage to the filter or to the presence of a back-flow (from permeate to feed). Confocal images demonstrated that the pressure release caused the migration of previously captured bacteriophage further into the depth of the filter. Data were analyzed using a modified internal polarization model, with the results providing important insights into the factors controlling virus retention during virus filtration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.