Some distillation columns in the chemical industry are operated in batch mode with a fairly short operating cycle. At the end of each cycle the columns are cooled and recharged. During the cooling cycle, air will be drawn into the column by the action of a vacuum relief valve.Consequently, for a finite portion of the operating cycle a flammable mixture will exist in the column.Here we maluate the risk posed by such a n operation to see if a mitigation measure is justified. We develop a fault tree and estimate the frequency of ignition by all possible ignition sources. By comparing the risk reduction attainable by installing a lightning protection system with that attainable by using an inert blanketing system the lightning protection system is found to be the preferred solution. It provides about the same risk reduction at a lower overall cost. 16-24 21 purge T ' O t 3 l S (11-15) X 6 + 16-24 99 0.1515 0.1212 0.3939 0.0606 0.0606 0.2121 1.0
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.