BackgroundNeonates with congenital diaphragmatic hernia and large defects often require patch closure. Acellular collagen matrices (ACM) have been suggested as an alternative to synthetic durable patches as they are remodeled by the host or could also be used for tissue engineering purposes.Materials and Methods2.0x1.0 cm diaphragmatic defects were created in 6-weeks old New-Zealand white rabbits. We compared reconstruction with a purpose-designed cross-linked ACM (Matricel) to 4-layer non-cross-linked small intestinal submucosa (SIS) and a 1-layer synthetic Dual Mesh (Gore-Tex). Unoperated animals or animals undergoing primary closure (4/0 polyglecaprone) served as age-matched controls. 60 (n = 25) resp. 90 (n = 17) days later, animals underwent chest x-ray and obduction for gross examination of explants, scoring of adhesion and inflammatory response. Also, uniaxial tensiometry was done, comparing explants to contralateral native diaphragmatic tissue.ResultsOverall weight nearly doubled from 1,554±242 g at surgery to 2,837±265 g at obduction (+84%). X-rays did show rare elevation of the left diaphragm (SIS = 1, Gore-Tex = 1, unoperated control = 1), but no herniation of abdominal organs. 56% of SIS and 10% of Matricel patches degraded with visceral bulging in four (SIS = 3, Matricel = 1). Adhesion scores were limited: 0.5 (Matricel) to 1 (SIS, Gore-Tex) to the left lung (p = 0.008) and 2.5 (Gore-Tex), 3 (SIS) and 4 (Matricel) to the liver (p<0.0001). Tensiometry revealed a reduced bursting strength but normal compliance for SIS. Compliance was reduced in Matricel and Gore-Tex (p<0.01). Inflammatory response was characterized by a more polymorphonuclear cell (SIS) resp. macrophage (Matricel) type of infiltrate (p<0.05). Fibrosis was similar for all groups, except there was less mature collagen deposited to Gore-Tex implants (p<0.05).ConclusionsMatricel induced a macrophage-dominated inflammatory response, more adhesions, had appropriate strength but a lesser compliance compared to native tissue. The herein investigated ACM is not a viable option for CDH repair.
Background
The breast is innervated by the intercostal nerves and the brachial plexus. We propose a technique to perform breast surgery without general anesthesia using the erector spinae plane (ESP) block and selective block of four nerves that arise from the brachial plexus innervate the breast and the axilla (SBP block).
Case
A 77-year-old man with breast cancer was scheduled for radical mastectomy and axillary clearance. He had a previous history of myocardial infarction with dilated cardiomyopathy and severely impaired ejection fraction. The surgery was performed under regional anesthesia with combined ESP and SBP block. The patient did not require opioids or other supplemental analgesics intra- or postoperatively and was discharged uneventfully.
Conclusions
SBP is a novel block that selectively blocks branches of the brachial plexus that innervate the breast.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.