The application of the carbon isotope separation method using plasma chemical reactions in carbon monoxide plasma for the recovery of 14 C from the graphite moderator of a dismantled Japanese gas-cooled reactor, Tokai Power Station, was evaluated numerically. The 14 C separation factor of 4.6 in one unit stage was estimated through the numerical simulation of a kinetic model in CO plasma. The calculated results show that the 14 C concentration in the cascade tail flow can be reduced to the environmental standard recommended by the International Commission on Radiological Protection (3 Bq/cm 3) and to the natural abundance level (1:3Â10 À4 Bq/cm 3) in 3 and 16 stages in the stripping section, respectively, and the amount of 14 C-enriched CO flow can be reduced to 1/10 3 and 1/10 6 of the feed CO amount in 9 and 19 stages in the enriching section, respectively. In the case of 3-stage processing in the stripping section and 9-stage processing in the enriching section, it is estimated that the total energy consumption by the plasma generator would be about 15 kW and the maximum inner diameter of the plasma reactor in the cascade would have to be about 60 cm.
The application of the carbon isotope separation method using plasma chemical reactions in carbon monoxide plasma for the recovery of 14 C from the graphite moderator of a dismantled Japanese gas-cooled reactor, Tokai Power Station, was evaluated numerically. The 14 C separation factor of 4.6 in one unit stage was estimated through the numerical simulation of a kinetic model in CO plasma. The calculated results show that the 14 C concentration in the cascade tail flow can be reduced to the environmental standard recommended by the International Commission on Radiological Protection (3 Bq/cm 3 ) and to the natural abundance level (1:3Â10 À4 Bq/cm 3 ) in 3 and 16 stages in the stripping section, respectively, and the amount of 14 C-enriched CO flow can be reduced to 1/10 3 and 1/10 6 of the feed CO amount in 9 and 19 stages in the enriching section, respectively. In the case of 3-stage processing in the stripping section and 9-stage processing in the enriching section, it is estimated that the total energy consumption by the plasma generator would be about 15 kW and the maximum inner diameter of the plasma reactor in the cascade would have to be about 60 cm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.