A test campaign for assessing the radiation hardness of different Erbium-doped garnet crystals including Er:YAG and a compositionally tuned Er:YAG/Er:LuAG mixed garnet is reported. Tests with proton and gamma radiation have been performed with parameters mimicking a 3-year low-earth-orbit satellite mission like MERLIN or ADM-Aeolus. For each test sample broadband transmission spectra in the wavelength range of 500 nm -1700 nm and characteristic laser curves from a test laser oscillator have been measured. Radiation-induced losses have been calculated from the obtained data. The results indicate that gamma radiation is the dominant loss source with about 0.5 %/cm radiation-induced losses for the nominal dose of the chosen mission scenario
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.