Phacoemulsification with IOL implantation in selected uveitic eyes was safe and effective. Acrylic IOLs provided a better visual outcome and lower complication rate than IOLs of other materials.
The Orbscan II pachymetry measurements correlated with the ultrasound measurements in eyes with clear corneas. Haze after PRK decreased the Orbscan pachymetry.
Purpose:To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. Settings: Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. Methodology: Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre-and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3). Results: Improvement in BCVA was statistically significant in both groups (P , 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P , 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P , 0.001). Conclusion: Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used.
Background:The purpose of this study was to evaluate the use of intralesional propranolol injection in the management of periocular capillary hemangioma.Methods:A prospective study was performed in 22 consecutive patients with periocular hemangioma. Twelve patients underwent intralesional propranolol injection and ten patients underwent intralesional triamcinolone injection. The size of the lesion was measured serially every week during the first month, every 2 weeks for the second month, and then monthly for another 2 months. The refractive error and degree of ptosis if present were measured before injection and at the end of the study.Results:There was reduction in the size of hemangioma, astigmatic error, and degree of ptosis in both groups. The difference in outcome between both groups was not statistically significant. Rebound growth occurred in 25% of the propranolol group and 30% of the steroid group but responded to reinjection. No adverse effects were reported during or after intralesional propranolol injection.Conclusion:Intralesional propranolol injection is an alternative and effective method for treatment of infantile periocular hemangioma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright 漏 2024 scite LLC. All rights reserved.
Made with 馃挋 for researchers
Part of the Research Solutions Family.