The titled system has been investigated using a single drop technique and flux (F) method of data treatment. In calculating fluxes, the time for drop formation and coalescence (∆t = 0.75 s) is considered. At lower concentration region of vanadium, V(V), the rate of V(V) transfer is directly proportional to its concentration. With the increase in [V(V)], slowly extractable V(V) species are formed gradually resulting in decrease in rate. Rate is directly proportional to the square root of [TOA]. It is reported that the most favorable extractable V(V) species exists in maximum amount at pH 2, and so, log F vs pH plots show a maximum at pH~2. ; as well as temperature; it is not possible to elucidate the value of rate constant (k) and mechanism in simple way.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.