Background Thoracic and abdominal aortic stent-grafts are firmer and more rigid than the native aorta. Aortic implanted devices have been implicated in the development of acute systolic hypertension, elevated pulse pressure, and reduced coronary perfusion. Case summary We report four cases of staged thoracic endovascular aortic repair (TEVAR) and then endovascular aneurysm repair (EVAR). All patients had TEVAR first for thoracic aortic aneurysm (TAA) and later on developed infra-renal abdominal aortic aneurysm (AAA) that required EVAR. There were three males and one female with a median age of 74.5 years (range 67.5 - 78.5). None of the patients developed aortic-related major clinical adverse effects or required any aortic intervention during their follow-up. However, within two years, all patients developed symptomatic left ventricular hypertrophy with diastolic dysfunction. All patients had bilateral lower limb oedema, with on and off chest pain and shortness of breath (SOB), necessitating coronary angiograms, which showed no evidence of coronary artery disease. Three patients died from cardiovascular-related morbidities, and the fourth patient is still complaining of SOB despite a normal coronary angiogram. Discussion Aortic-endograft compliance mismatch is an invisible enemy, with troubling consequences for the aorta proximal and distal to the endograft. Aortic stiffness due to vascular endograft could lead to cardiovascular adverse events, even in the absence of direct aortic-related complications. After combined TEVAR and EVAR, the compliance mismatch and elasticity loss are even more pronounced than with TEVAR alone, which necessitates patient monitoring for the development of cardiovascular complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.