α-bisabolol, and ascorbyl tetraisopalmitate, respectively. The calibration curves showed good linearity with determination coefficients (R 2 ) ≥ 0.999. The mean recoveries were ranged between 89.8 and 103.9 % with relative standard deviations (RSDs) <5 %. The intra-and inter-day precision was <2 %. The limits of detection (LODs) were 0.03, 0.4, and 4.02 μg mL −1 for glabridin, (−)-α-bisabolol, and ascorbyl tetraisopalmitate, respectively. The method was successfully applied for monitoring 11 market samples, in which glabridin was quantified in the range of 17.5-25 mg 100 g −1 , (−)-α-bisabolol in the range of 25.1-677 mg 100 g −1 , and 140.6-291.5 mg 100 g −1 for ascorbyl tetraisopalmitate. The proposed analytical method is simple, sensitive, and versatile and can be used for the quantification of lipophilic compounds in cosmetics in a single chromatographic run.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.