With the increase of general knowledge and the advancement of science and technology, antibacterial substances were used more than antibiotics. In our current study, the antibacterial virtues of CFO/BiOI nanocomposite were investigated due to its high importance on Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa and Bacillus cereus. MIC, MBC , Disk Diffusion and IC50 tests Cefalotin (CF), Amoxicillin (AMX), Gentamicin (GM), Trimethoprim-sulphamethoxazole (SXT) and Ceftriaxone (CRO) antibiotics in concentration 30W, 10i, 10t , 25h and 30 were used to find the antibacterial properties of the synthesized nanocomposite, respectively. For the synthesis of nanocomposites polyethylene glycol (PEG) and sulfonic acid was used as a solvent. It is noteworthy that the synthesis was performed by heat dissolution method without the presence of surfactant. Also, various techniques such as X-Ray Diffraction(XRD), Scanning Electron Microscope (SEM), High resolution mapping and Energy Dispersive X-ray spectroscopy (EDAX) have been used to determine the properties of produced nanocomposites. SEM test results showed that the formed nanoparticles were globular and their size was limited area of 22 to 34 nm. The results showed CFO / BiOI nanocomposite exhibits strong significant biological activity against Bacillus cereus. The results of MBC (Minimum Bactericidal Concentration) and MIC (Minimum Inhibition Concentration) tests for CFO/BiOI nanocomposites on bacteria were examined in the range of 0.12-0.48 mg/ml and 0.06 to 0.24 mg/ml respectively. According to the results, the minimum IC50 value was determined at a concentration of 0.061 mg/ml. On the other hand, the most resisting and susceptible bacteria in this method were Pseudomonas aeruginosa and Bacillus cereus, respectively. These findings are identical to those of a prior study on CoFe2O4 nanoparticles antibacterial properties. MBC of the nanocomposites, 50 µl from all the tubes that showed no obvious bacterial growth were distributed on BHI agar plates and incubated for 24 h at 37 ◦C. The MBC endpoint is defined as the lowest concentration which killed 98% of the bacterial population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.