Implantation of a synthetic midurethral sling (SMUS) is the most commonly performed anti-incontinence operation in women worldwide. The effectiveness of the SMUS is comparable to that of the historical gold standards--autologous fascial slings and the Burch colposuspension. Much controversy, however, has evolved regarding the safety of this type of sling. Overall, the quality of the studies with respect to assessing risks of SMUS-associated complications is currently poor. The most common risks in patients with SMUS include urethral obstruction requiring surgery (2.3% of patients with SMUS), vaginal, bladder and/or urethral erosion requiring surgery (1.8%) and refractory chronic pain (4.1%); these data likely represent the minimum risks. In addition, the failure rate of SMUS implantation surgery is probably at least 5% in patients with stress urinary incontinence (SUI). Furthermore, at least one-third of patients undergoing sling excision surgery develop recurrent SUI. Considering the additional risks of refractory overactive bladder, fistulas and bowel perforations, among others, the overall risk of a negative outcome after SMUS implantation surgery is ≥15%.
We report on an experimental study of the role of mode of delivery and pregnancy on the architecture of vaginal elastic fibers and vaginal vault elasticity in female Sprague-Dawley rats. In primiparous rats submitted to spontaneous or Cesarean delivery and virgin rats submitted to simulated delivery, the tortuosity of elastic fibers (defined as the ratio of length to end-to-end distance) was observed to decrease when measured two days to two weeks postpartum. In addition, the measured tortuosity of elastic fibers in multiparous rats was greater than that of virgin rats. The tortuosity of elastic fibers of all rats measured at two days postpartum were found to be similar to that of multiparous rats. At two weeks postpartum the measured tortuosity of vaginal elastic fibers was indistinguishable from virgin rats, regardless of the delivery method. Borrowing from the field of polymer physics, a model is suggested that connects elastic fiber tortuosity to the resulting tension under an applied stress; fibers having high tortuosity are expected to provide less structural support than more linear, low tortuosity fibers. To probe the macroscopic effects in elasticity due to architectural changes observed in elastic fibers, we have measured the stiffness of the vaginal vault in each cohort using a pressure-infusion system. The vaginal vault stiffness of all primiparous rats measured two weeks postpartum was greater than that measured two days postpartum. In addition, the vaginal vault of virgin rats was stiffer than that of multiparous rats. These observations confirmed that vaginal vault elastic fibers undergo significant remodeling due to pregnancy and parturition, and that the complex remodeling may be a significant contributor to tissue elasticity. Remarkably, regardless of the mode of delivery or simulated tissue trauma, elastic fiber tortuosity is observed to decrease from two days to two weeks postpartum indicating the onset of repair and recovery of tissue stiffness.
Introduction Transanal total mesorectal excision (TaTME) has rapidly emerged as a novel approach for rectal cancer surgery. Safety profiles are still emerging and more comparative data is urgently needed. This study aimed to compare indications and short‐term outcomes of TaTME, open, laparoscopic, and robotic TME internationally. Methods A pre‐planned analysis of the European Society of Coloproctology (ESCP) 2017 audit was performed. Patients undergoing elective total mesorectal excision (TME) for malignancy between 1 January 2017 and 15 March 2017 by any operative approach were included. The primary outcome measure was anastomotic leak. Results Of 2579 included patients, 76.2% (1966/2579) underwent TME with restorative anastomosis of which 19.9% (312/1966) had a minimally invasive approach (laparoscopic or robotic) which included a transanal component (TaTME). Overall, 9.0% (175/1951, 15 missing outcome data) of patients suffered an anastomotic leak. On univariate analysis both laparoscopic TaTME (OR 1.61, 1.02–2.48, P = 0.04) and robotic TaTME (OR 3.05, 1.10–7.34, P = 0.02) were associated with a higher risk of anastomotic leak than non‐transanal laparoscopic TME. However this association was lost in the mixed‐effects model controlling for patient and disease factors (OR 1.23, 0.77–1.97, P = 0.39 and OR 2.11, 0.79–5.62, P = 0.14 respectively), whilst low rectal anastomosis (OR 2.72, 1.55–4.77, P < 0.001) and male gender (OR 2.29, 1.52–3.44, P < 0.001) remained strongly associated. The overall positive circumferential margin resection rate was 4.0%, which varied between operative approaches: laparoscopic 3.2%, transanal 3.8%, open 4.7%, robotic 1%. Conclusion This contemporaneous international snapshot shows that uptake of the TaTME approach is widespread and is associated with surgically and pathologically acceptable results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.