Patients with AF recurrence following RFA have a higher mean LAV/LAVi compared to patients with no recurrence. Large LAV/LAVi increases the odds of AF recurrence post RFA.
CRT may significantly reduce risk of VA compared with ICDs in patients who meet criteria for CRT. CRT responders have significant reduction in VA compared with nonresponders. CRT nonresponse might significantly increase risk of VA.
Defibrillation threshold (DFT) testing has been an integral part of implantable cardioverter‐defibrillator (ICD) implantation to confirm appropriate sensing of ventricular fibrillation and to establish an adequate safety margin for defibrillation. However, there is a lack of evidence regarding benefits of routine DFT testing. Therefore, we performed a meta‐analysis to assess its mortality benefit. We searched MEDLINE for studies comparing mortality outcomes in ICD recipients who underwent DFT testing to those who did not. For the second analysis, studies comparing outcomes in patients with high‐ vs low‐energy DFT were included. Odds ratio and standard errors were calculated, and inverse variance method in a random‐effect model was used to combine effect sizes. Fifteen studies with 10,975 subjects comparing outcomes in patients who underwent routine DFT testing during ICD implantation and those who did not were included. There was no difference in the group that did not undergo DFT testing with regards to all‐cause mortality (OR 0.935; CI 0.725‐1.207; P = 0.606), cardiac mortality (OR 0.709; CI 0.385‐1.307; P = 0.271), noncardiac mortality (OR 0.921; CI 0.701‐1.210; P = 0.554), and arrhythmic mortality (OR 1.152; CI 0.831‐1.596; P = 0.396). Percentage of successful appropriate first shocks among the two groups showed no difference. Five studies with 2278 subjects were included in the second analysis comparing patients with low DFT vs high DFT. Patients with high DFT had no significant increase in all‐cause mortality compared to patients with low DFT (OR 0.527; CI 0.034‐8.107; P = 0.646). Patients requiring higher DFT had no increased all‐cause mortality compared to patients with lower DFT. Routine DFT testing during ICD implantation does not confer any significant benefit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.