Endotracheal intubation was successfully accomplished with 70° rigid nasendoscope under video guidance in two patients in whom repeated attempts to secure airway with flexible fibreoptic bronchoscope were unsuccessful. Both patients had compromised airway (laryngeal papillomatosis and a huge thyroid swelling) and were uncooperative. Frova intubating introducer was used along with 70° rigid nasendoscope to accomplish tracheal intubation under video guidance.
We describe the anaesthetic management using i-gel for airway maintenance in a patient with kyphoscoliosis presenting for emergency caesarean section due to fetal distress and scar tenderness. The patient had a history of previous caesarean section under general anaesthesia, and presently her cardiorespiratory status is stable. We used i-gel, the new supraglottic airway device, for maintaining the airway under intravenous anaesthesia using propofol.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.