The use of personal protective equipment (PPE) is required for the self-protection of healthcare workers during cardiopulmonary resuscitation (CPR) in patients at risk of aerosol transmission of infectious agents. The aim of this study was to analyze the impact of personal protective equipment on physiological parameters during CPR. A randomized, quasi-experimental, crossover design was used. The study was carried out in a training and simulation emergency box and the total sample consisted of 20 healthcare professionals. Two CPR tests were compared with the recommended sequence of 30 chest compressions and 2 ventilations. The duration of each test was 20 min. One of the CPR tests was carried out without using any PPE (CPR_control), i.e., performed with the usual clothing of each rescuer. The other test was carried out using a CPR test with PPE (i.e., CPR_PPE). The main variables of interest were: CPR quality, compressions, ventilations, maximum heart rate, body fluid loss, body temperature, perceived exertion index, comfort, thermal sensation and sweating. The quality of the CPR was similar in both tests. The maximum heart rate was higher in the active intervals (compressions + bag-valve-mask) of the test with PPE. CPR_PPE meant an increase in the perceived effort, temperature at the start of the thermal sensation test, thermal comfort and sweating, as opposed to CPR performed with usual clothing. Performing prolonged resuscitation with PPE did not influence CPR quality, but caused significant physiological demands. Rescuers were more fatigued, sweated more and their thermal comfort was worse. These results suggest that physical preparation should be taken into account when using PPE and protocols for physiological recovery after use should also be established.
Objective: This study focuses on the characteristics (feasibility, resuscitation quality, and physical demands) of infant cardiopulmonary resuscitation (CPR) on the forearm during fast walking, performed by a trained lay rescuer.Methods: Twenty-one university students from the infant education degree participated in a randomized crossover simulation study to compare a standard pediatric CPR versus a walking pediatric CPR with a manikin on the rescue forearm. Each rescuer performed 2 resuscitation tests of 2 minutes on the infant manikin. Cardiopulmonary resuscitation, physiological, and perceived effort variables were measured.
Results:The quality of chest compressions was higher in standard pediatric CPR than in walking pediatric CPR (72% vs 51%; P < 0.001) and overall CPR quality (59% vs 49%; P = 0.02). There were no differences between ventilation quality (47% vs 46%). Walking pediatric CPR presented a higher percentage of maximum heart rate (52% vs 69%; P < 0.001) and perceived exertion rate (2 vs 5; P < 0.001). Participants walked an average of 197 m during the test.
Conclusions:In conclusion, pediatric walking CPR is feasible although it represents a slight quality decrease in a simulation infant CPR setting. The option "CPR while walking fast to a safe place" seems to be suitable in terms of safety both for the victim and the rescuer, as well as CPR quality in special circumstances.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.