Background : The combined use of liquid media and solid media is recommended for mycobacterial culture. We evaluated diagnostic performance of combination of BACTEC Mycobacteria Growth Indicator Tube (MGIT; Becton Dickinson, USA) and 2% Ogawa media (Korean Institute of Tuberculosis, Korea) for recovery of mycobacteria.Methods : In September 2007, 1,764 specimens from 1,059 patients were cultured with MGIT and Ogawa. Acid fast bacilli (AFB) smear was fluorochrome-stained. The isolates were identified into Mycobacterium tuberculosis (MTB) and nontuberculous mycobacteria (NTM) with PCR using Seeplex TB Detection Kit (Seegene, Korea). Recovery rate, time to detection (TTD), contamination rate, mixed growth rate and species distribution were analyzed.Results : Two hundred thirty-five specimens (13.3%) from 165 patients (15.6%) were positive for mycobacterial culture. Recovery rates of mycobacteria from the group using both media, MGIT only, and Ogawa only were 13.3%, 12.1%, and 7.8%, respectively. While MGIT recovered 98.9% of MTB and 79.7% of NTM, Ogawa recovered 65.9% of MTB and 54.1% of NTM. TTDs of total mycobacteria/MTB/NTM in MGIT and Ogawa were 10.6/11.4/9.7 days and 31/29/33 days, respectively. MGIT TTDs of total mycobacteria/MTB/NTM from AFB-positive specimens were significantly shorter than those of AFB-negative specimens; 8.2/9.5/4.4 days vs 11.6/12.7/10.7 days. Contamination and mixed growth rate of MGIT were 9.6% and 3.7%. Primary culture of Ogawa recovered 1 MTB and 1 NTM among the 170 MGIT-contaminated specimens and 38 mycobacteria among 66 specimens that showed mixed cultures of MGIT.Conclusions : MGIT warrants sensitive and rapid isolation of mycobacteria. However, the combination of MGIT and Ogawa is more desirable to recover mycobacteria in the case of contaminations or mixed cultures. (Korean J Lab Med 2008;28:299-306)
Background : Fecal occult blood tests (FOBTs) have been widely used as a means of colorectal cancer screening. Automated FOBTs using immunologic principles have the advantages such as quantitation, high specificity, and high throughput. We evaluated a newly-introduced automated FOBT analyzer, OC-SENSOR neo (OC neo) (Eiken Chemical Co., Japan).Methods : The precision, linearity, and carry-over rate of OC neo were assessed with specimens prepared in accordance with the guidelines of CLSI. We performed a parallel test between OC neo and OC-SENSOR I (OC I) (Eiken Chemical Co.) using 300 consecutive stool specimens and 60 OC I-positive specimens. The results were analyzed with SPSS version 13.0 (SPSS Inc., USA).Results : The coefficients of variation (CV) of within-run, between-run, and between-day using OCControl L (Eiken Chemical Co.) of ca. 150 ng/mL were 3.5-7.8%, 4.5-8.8% and 4.9-5.0%, respectively. The linear regression coefficient and carry-over rate with the range of 67.8-939.4 ng/mL were 0.9998 (P<0.001), and 0.1%, respectively. Correlation coefficient between OC neo and OC I was R
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.