The purpose of this study was to evaluate the effect of single-energy metal artifact reduction (SEMAR) for metal artifacts using CT images reconstructed with adaptive iterative dose reduction three dimensional (AIDR3D) and advanced intelligent clear-IQ engine (AiCE) in calibration-eld of view of various sizes. A prosthetic hip joint was arranged at the center of the phantom. The phantom images were scanned by changing calibration-eld of view of 320 mm and 500 mm, and were reconstructed using ltered back-projection (FBP), AIDR3D, and AiCE with and without SEMAR, respectively. The metal artifact reduction with SEMAR was evaluated by calculated the relative artifact index value and visual scores in degree of artifact by seven radiology technologists. Relative artifact index of FBP, AIDR3D, and AiCE with 320 mm/500 mm calibration-eld of views were 10.2/10.0, 16.3/16.4, and 17.8/17.9 without SEMAR, 3.3/3.1, 2.6/2.5, and 2.3/2.0 with SEMAR, respectively. Visual scores were not signi cantly different between 320 mm and 500 mm calibration-eld of views in all reconstruction methods. The effect of metal artifact reduction was not affected by calibration-eld of view sizes in the SEMAR combined with AIDR3D or AiCE.
The purpose of this study was to evaluate the effect of single-energy metal artifact reduction (SEMAR) for metal artifacts using CT images reconstructed with adaptive iterative dose reduction three dimensional (AIDR3D) and advanced intelligent clear-IQ engine (AiCE) in calibration-field of view of various sizes. A prosthetic hip joint was arranged at the center of the phantom. The phantom images were scanned by changing calibration-field of view of 320 mm and 500 mm, and were reconstructed using filtered back-projection (FBP), AIDR3D, and AiCE with and without SEMAR, respectively. The metal artifact reduction with SEMAR was evaluated by calculated the relative artifact index value and visual scores in degree of artifact by seven radiology technologists. Relative artifact index of FBP, AIDR3D, and AiCE with 320 mm/500 mm calibration-field of views were 10.2/10.0, 16.3/16.4, and 17.8/17.9 without SEMAR, 3.3/3.1, 2.6/2.5, and 2.3/2.0 with SEMAR, respectively. Visual scores were not significantly different between 320 mm and 500 mm calibration-field of views in all reconstruction methods. The effect of metal artifact reduction was not affected by calibration-field of view sizes in the SEMAR combined with AIDR3D or AiCE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.