A label-free electrochemical aptamer-based sensor has been fabricated for alpha-fetoprotein (AFP) detection. Platinum nanoparticles on carboxylated-graphene oxide (PtNPs/GO-COOH) modified screen-printed graphene-carbon paste electrode (SPGE) was utilized as an immobilization platform, and the AFP aptamer was employed as a bio-recognition element. The synthesized GO-COOH helps to increase the surface area and amounts of the immobilized aptamer. Subsequently, PtNPs are decorated on GO-COOH to enhance electrical conductivity and an oxidation current of the hydroquinone electrochemical probe. The aptamer selectively interacts with AFP, causing a decrease in the peak current of the hydroquinone because the binding biomolecules on the electrode surface hinder the electron transfer of the redox probe. Effects of aptamer concentration and AFP incubation time were studied, and the current changes of the redox probe before and after AFP binding were investigated by square wave voltammetry. The developed aptasensor provides a linear range from 3.0–30 ng mL−1 with a detection limit of 1.22 ng mL−1. Moreover, the aptamer immobilized electrode offers high selectivity to AFP molecules, good stability, and sensitive determination of AFP in human serum samples with high recoveries.
A novel ultrasonic flow injection chemiluminescence (FI-CL) manifold for determining hydrogen peroxide (H2O2) has been designed and evaluated. Chemiluminescence obtained from the luminol-H2O2-cobalt(II) reaction was enhanced by applying 120 W of ultrasound for a period of 4 s to the reaction coil in the FI-CL system and this enhancement was verified by comparison with an identical manifold without ultrasound. The system was developed for determining ultra-trace levels of H2O2 and a calibration curve was obtained with a linear portion over the range of 10-200 nmol L(-1) H2O2 (correlation coefficient 0.9945). The detection limit (3sigma) and the quantification limit (LOQ) were found to be 1 x 10(-9) and 3.3 x 10(-9) mol L(-1) respectively and the relative standard deviation was 1.37% for 2 x 10(-7) mol L(-1) H2O2 (n = 10). The method was applied to the determination of trace amounts of H2O2 in purified water and natural water samples without any special pre-treatments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.