The aim of this study was to elucidate the presence of vitamin E homologues in medicinal plants. To identify various homologues in the matrix of medicinal plant samples, a method for simultaneous determination was developed using ESI(+)-LC-MS3. A complete separation of each homologue was achieved within 20 min using a PFP column and an isocratic elution system of water/methanol (10:90, v/v) at a flow rate of 0.5 mL/min. The ESI-MS condition for each homologue was optimized, and the m/z value and the fragmentation pathway of each homologue were summarized. This LC-MS3 method made it possible to detect the homologues without the effect of matrix; therefore, high sensitive analysis was established, and then, the MS3 makes it possible to extract from plants with methanol only. The LC-MS3 method was applied to identify the eight vitamin E homologues in 11 medicinal plants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.