The decreased salivary concentration of EGF in adults with LPR suggests that a deficiency in this polypeptide could be associated to the disease.
BACKGROUND: Prolonged monitoring increased our knowledge on gastroesophageal reflux (GER), and the disease became known as gastroesophageal reflux disease (GERD). Prolonged reflux monitoring permits the diagnosis of GERD when endoscopic findings are not enough to characterize it. OBJECTIVE: The objective of this paper is to review the current knowledge on impedance-pH monitoring, taking into account the published literature and the authors experience with 1,200 exams. METHODS: The different types of prolonged reflux monitoring, namely: conventional pHmetry, catheter-free pHmetry and impedance-pHmetry will be briefly described. The new possibilities of evaluation with impedance-pHmetry are emphasized, namely: the study of symptomatic patients in use of proton pump inhibitors (PPIs); evaluation of patients with symptoms suggestive of GERD although with normal endoscopy and normal pHmetry, diagnostic elucidation of patients with atypical symptoms or supra-esophageal symptoms, mainly chronic cough, study of patients complaining of belch, differentiating gastric and supra-gastric belching, and the proper work-up before anti-reflux surgery. RESULTS: When impedance was associated to pH monitoring, an impressive technological evolution became apparent, when compared to pH monitoring alone. The main advantages of impedance-pHmetry are: the ability to detect all types of reflux: acid, non-acid, liquid, gaseous. In addition, other important measurements can be made: the ability of the esophagus in transporting the bolus, the measurement of basal mucosal impedance and the evaluation of primary peristalsis post reflux. CONCLUSION: Impedance-pHmetry is a promising method, with great advantages over conventional pHmetry. The choice between these two types of monitoring should be very judicious. The authors suggest the importance of careful evaluation of each reflux episode by the physician responsible for the examination, necessary for the correct interpretation of the tracings.
BACKGROUND: The high-resolution manometry has been a significant advance in esophageal diagnostics. There are different types of catheter and systems devices to capture esophageal pressures that generate variable data related to Chicago Classification (CC) and consequently influence normal values results. There are not normative data for the 24-channel water-perfused high-resolution manometry system most used in Brazil with healthy volunteers in supine posture. OBJECTIVE: To determine manometric esophageal normative values for a 24-channel water-perfused high-resolution manometry catheter in supine posture using healthy volunteers according to CC 3.0 parameters. METHODS: A total of 92 volunteers with no gastrointestinal symptoms or medications affecting GI motility underwent esophageal high-resolution manometry by standard protocol. Age, gender and manometry parameters analyzed using Alacer software were collected. The median, range, and 5th and 95th percentiles (where applicable) were obtained for all high-resolution manometry metrics. Normal value percentiles were defined as 95th integrated relaxation pressure, 5th-100th distal contractile integral, and 5th distal latency. RESULTS: The mean age was 40.5±13.2 years. Our normative metrics were integrated relaxation pressure <16 mmHg and distal contractile integral (708-4111 mmHg.cm.s) distal latency was <6 s and peristaltic break size (>4 cm). For EGJ-CI the range 5th-95th was 21.7-86.9 mmHg.cm.s. CONCLUSION: This is the first report of normative data for the 24-channel water-perfused system in supine posture. It revealed higher integrated relaxation pressure and distal latency duration which suggest the need to change CC 3.0 cutoffs for this system. It is observed that there is a tendency that DCI >7000 mmHg.cm.s may represent the lower limit of hypercontractility, and when <700 mmHg.cm.s (<5% percentile) interpreted as ineffective esophageal motility or failcontraction. Also compared to Chicago 3.0, higher integrated relaxation pressure and duration of distal latency were found. We emphasize that these data must be confirmed by future studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.