Occlusal force has the main role in determining the teeth health in general and determining the chewing, muscle and TMJ function. The objective of this study was to find if there was any relation between the preferred chewing side and the force, measured by T-scan III system. The total number of 90 (46 female and 44 male) dental students was included in this study. They were asked whether their preferred chewing side was right, left or both. Afterwards, the occlusal forces in habitual occlusion, using T-Scan III Electronic device (IP-CO position mode, MA-mode, MA sensitivity setting) were measured. The data were presented as Mean ± SD. Spearman correlation was used to find the correlation between the occlusal force and chewing side. Differences in P < 0.05 were considered significant. There were 90 subjects (46 female and 44 male) mean age 23.3 (SD ± 2.2 years) included in the study. The preferred chewing side of 42 subjects was the right side, 24 of them preferred the left side and the other 24 preferred both sides as the chewing side. Occlusal force was higher in the preferred chewing side (P < 0.05) but using Spearman correlation, there was no statistical significance of occlusal force between the groups, the left side (r = −0.143, P > 0.05) and the right side (r = 0.143, P > 0.05) according to the preferred chewing side. In this study, the relation between the preferred chewing side and occlusal force was found.
The maxillary second molar contains three roots and three canals. Variations of the maxillary second molar are reported in numerous studies in vitro and in vivo. Dentists are required to have adequate knowledge related to root canal morphology and their possible variations. The aim of this study was to present a case report about a diagnosis and treatment in maxillary second molar with single root and single canal. It is concluded that the diagnosing of these unusual cases is of high importance for successful endodontic treatment of these teeth.
The advantage of electronic devices is to eliminate the subjectivity. Based on individual capabilities, visual perception has its disadvantages. The aim of this study was to find out the possible shade difference between the upper and lower teeth, visual perception versus spectrophotometry as well as proving that females are better in visual perception of colour matching. 82 subjects (dental students) of this study determined the color of each other's natural teeth. The color of 1640 teeth (incisors, canines and premolars), was matched by visual perception and by Vita Easyshade spectrophotometer. The matching was focused on the middle third of buccal surfaces of the examined teeth. In this study, it was found that there was a difference of color between the teeth of the upper and lower jaw. The percentage of the accordance between two methods was 28.35% for all examined teeth. The color determination at central incisors showed the highest value of accordance 40.85%. Based on Vitapan 3D Mastershade, the most frequent color was 2M2.
Background A hermetic seal at the apical terminus is required for healthy periradicular tissue. Root canal obturation sealers that are used in endodontics are based on zinc oxide eugenol, calcium hydroxide, resins, glass ionomers, silicone, or bioceramics, but no optimal sealer material has been identified to date. Therefore, the aim of this in vitro study was to evaluate apical leakage after crown-down preparation and root canal obturation with Endomethasone N, glass ionomer cement, and EndoRez sealers. Material/Methods For this in vitro study, we tested 92 extracted human teeth, which were divided into 3 groups after a preparation technique and obturation with Endomethasone N sealer, glass ionomer cement, and EndoRez sealer in combination with Thermafil obturator. Apical leakage was evaluated and compared among the tested groups using a dye leakage method through a stereomicroscope. The values were measured from the apex to the coronal extent of dye penetration. For statistical analysis, the t test was used for comparison of the arithmetic averages of tested groups. Results After preparation with rotary files, tested groups obturated with Thermafil obturator in combination with Endomethasone sealer showed higher average dye penetration than tested groups obturated with EndoRez and glass ionomer sealer. Conclusions Although all experimental groups showed dye leakage, the glass ionomer sealer in combination with Thermafil showed the least leakage, compared with EndoRez and Endomethason N.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.