Activity of both the M- and P-forms of sulphotransferase (ST) was measured in platelets from patients with migraine, tension headache and controls. Mean PST values were 0.065 +/- 0.023 and 0.057 +/- 0.052 nmol/mg protein/min for migraine patients with and without aura. The corresponding values for tension headache and controls were 0.122 +/- 0.059 and 0.127 +/- 0.093 nmol/mg protein/min respectively (p < 0.05). Mean MST values were not different for any of the groups, and MST and PST activities measured in two patients during a migraine attack were not significantly altered from baseline levels. Mean plasma inorganic sulphate concentrations and paracetamol metabolites were not significantly different in any of the groups studied. The results suggest that PST activity may be a factor in the aetiology of migraine.
Introduction Digital breast tomosynthesis (DBT) may improve the accuracy of mammography by enabling visual separation of overlapping tissues (Andersson et al. 2008, Poplack et al. 2007). Methods Following local research ethics approval, all women attending the assessment clinic for evaluation of a mammographic abnormality found on routine screening (film-screen) were invited to take part in the study subject to informed consent. Participants underwent bilateral two-view two-dimensional (2D) digital mammography and bilateral twoview DBT. Mammography scores using the RCR Breast Group classification were sequentially obtained for the screening mammogram, 2D digital and DBT, and these were each compared with the final assessment outcome. Results Ninety-one percent of eligible women participated. Results from the first 300 participants are presented in Table 1 below. Kappa coefficients for agreement of each imaging method with final assessment outcome were calculated. Screening mammograms had the lowest agreement with the final outcome (Kappa = 0.02; P = 0.22), 2D digital mammography was better (Kappa = 0.26; P = 0.0000) and DBT had the highest score (Kappa = 0.37; P = 0.0000). Conclusion The preliminary results of this ongoing study show that DBT increases the diagnostic confidence of the radiologist. This supports the need for a larger multicentre study. Markers of screen reading performance (overall and first reader cancer detection rates, recall rates, positive predictive value of recall and missed cancers) were compared with volume of films read. Readers were categorised into four groups, according to film reading volume over the 3-year period: <15,000 (that is, on average less than the recommended 5,000/year); 15,000 to <20,000; 20,000 to <25,000; and ≥25,000. Statistical analysis was undertaken using SPSS for Windows version 13. Results The recall rate in low volume readers (<5,000/year) was 6.9% and was significantly higher than in the other groups combined (4.8%; P ≤ 0.001). These readers also had a lower positive predictive value than higher volume readers (11.7% versus 15.7%, P ≤ 0.001).The cancer detection rate at first read was significantly lower in the higher volume readers (≥25,000) in comparison to the other groups combined (6.6 per 1,000 versus 8.2 per 1000, P ≤ 0.001). Conclusion These data support the recommendation that readers should read a minimum of 5,000 mammograms/year. They also suggest that there is an upper limit above which reader performance deteriorates (in terms of cancer detection). With the imminent programme expansion this has implications for service quality. Consideration should be given to the introduction of an upper limit of mammographic reads.
O2
Breast Cancer Research
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.