3. Shingleton BJ, Nguyen BKC, Eagan EF, Nagao K, O'Donoghue MW. Outcomes of phacoemulsification in fellow eyes of patients with unilateral pseudoexfoliation: single-surgeon series. J Cataract Refract Surg 2008; 34:274-279 4. Poley BJ, Lindstrom RL, Samuelson TW. Long-term effects of phacoemulsification with intraocular lens implantation in normotensive and ocular hypertensive eyes. J Cataract Refract Surg 2008; 34:735-742 5. Shingleton BJ, Gamell LS, O'Donoghue MW, Baylus SL, King R. Long-term changes in intraocular pressure after clear corneal phacoemulsification: normal patients versus glaucoma suspect and glaucoma patients. J Cataract Refract Surg 1999; 25:885-890 6. Merkur A, Damji KF, Mintsioulis G, Hodge WG. Intraocular pressure decrease after phacoemulsification in patients with pseudoexfoliation syndrome.Partial coherence interferometry (PCI) has an 8% to 22% failure rate for a variety of reasons such as mature cataract, inability to fixate secondary to macular degeneration, tremor, keratopathy, nystagmus, and vitreous hemorrhage. 1-4 The new composite IOLMaster version 5 software has demonstrated a failure rate of 7.4%, primarily because of posterior subcapsular cataracts. 5 Few studies of the efficacy of PCI in a teaching hospital setting have been done. We investigated the PCI failure rate with the IOLMaster (Carl Zeiss Meditec) in a resident ophthalmology clinic at a Veterans Affairs hospital.After investigative review board approval was obtained, the biometric measurements of 147 consecutive patients (165 eyes) who had resident-performed cataract surgery from September 2007 to June 2008 were examined. Thirty-nine patients (42 eyes) were excluded because of incomplete electronic medical records (EMRs). One hundred eight patients (123 eyes) met the inclusion criteria; 106 were men (98.1%). The mean age of the patients was 72.4 years (range 50 to 91 years). Forty-six eyes (37.4%) were documented PCI failures that required immersion A-scan for axial length determination. The subgroup of 88 eyes that had IOLMaster version 4 readings had a failure rate of 43.2%, whereas the subgroup of 35 eyes with IOLMaster version 5 readings had a significantly lower failure rate of 22.9% (odds ratio Z 0.38, P!.05). All PCI failures were due to dense cataract. The mean preoperative best corrected visual acuity (BCVA) was 20/60 in those who had successful PCI compared with !20/400 in those requiring immersion A-scan (P Z.01).The limitations of this study include the retrospective nature, variability in measurements secondary to different resident physicians performing PCI, small sample size, a large number of exclusions due to incomplete EMRs, and inability to analyze the PCI failures by type of cataract because of variable grading of cataracts.The study suggests that the PCI biometry failure rate is still significant in the veteran population due to dense cataracts, although the version 5 software appears to decrease this rate. The study also suggests that poor preoperative vision is a predictor of PCI failure. We look f...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.