A novel method of ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed for the identification and quantification of four potential genotoxic impurities (PGIs) in the active pharmaceutical ingredients of TSD-1, a novel P2Y12 receptor antagonist. Four PGIs were named, 4-nitrobenzenesulfonic acid, methyl 4-nitrobenzenesulfonate, ethyl 4-nitrobenzenesulfonate, and isopropyl 4-nitrobenzenesulfonate. Following the International Conference of Harmonization (ICH) guidelines, this methodology is capable of quantifying four PGIs at 15.0 ppm in samples of 0.5 mg/mL concentration. This validated approach presented very low limits (0.1512–0.3897 ng/mL), excellent linearity (coefficients > 0.9900), and a satisfactory recovery range (94.9–115.5%). The method was sufficient in terms of sensitivity, linearity, precision, accuracy, selectivity, and robustness and, thus, has high practicality in the pharmaceutical quality control of TSD-1.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.