SUMMARYDevelopment of sodium-immersed-type Electromagnetic Pumps (EMP) is expected to improve reliability, safety, maintainability, and construction cost of the Fast Breeder Reactor (FBR) compared with the conventional mechanical pumps. To realize the EMP, establishment of a high-temperature-resistant electrical insulating system is indispensable.A mica-alumina combination is selected for the insulating system at temperatures higher than 500°C.Using this insulating system, an aging pretest was performed. The aging condition was to apply 1.5-kV ac voltage in the nitrogen atmosphere at 550°C for 4000 hours. The dielectric properties before and after the aging were measured to understand the tendency of temporal change in the aging.In this result, the dielectric performance after aging was improved compared with the initial performance. The curious phenomenon was clarified to be caused by a decrease of organic component in the insulation, which remained due to incomplete burning. Also, the possibility of thermal runaway was considered to be higher as a dielectric breakdown mechanism.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.