OBJECTIVE: To assess the impact of applying active thermal protection by diving specialists based on electric heating to ensure thermal comfort as a part of a series of measures to prevent occupational diseases while performing underwater works under low ambient temperature.MATERIALS AND METHODS: The test evaluated the time spent by divers in the water maintaining thermal comfort without active heating and using the system of electric heating. The diver’s thermal comfort was estimated according to subjective sensations. The test was held using the diving equipment SLVI-71, SSP-М, SN-21, GVS ХС1200, SVG-200, SVC «Amphora», SVU-5/1, SVU-3 with АВМ-12к, at depth from 2 m to120 m, at a water temperature from +1° С to +16° С.RESULTS: The test determined the compatibility of the electric heating developed system for divers with components of special diving equipment of the above types; showed the necessity of applying the elements of hands and feet’s warming as a part of the heating system; proved the positive impact of the heating system on divers in the period of maintaining thermal comfort while performing diving works, including different levels of heating power.DISCUSSION: Diver’s hypothermia predisposes to oxygen starvation, contributes to the emergence of decompression sickness, oxygen and carbon dioxide poisoning. The average time of providing divers thermal comfort by using FEC at a water temperature from +1° С to +4° С exceeds 3,5–4,6 times the period of the diver’s staying in the water without using active heating. Using elements of hands and feet’s warming in the electric heating suit provides decrease in appearance of primary hypothermia signs of the extremities, contributing to the maintenance of the diver’s optimum heat sensation for a long time. Applying electric heating system significantly reduces the risk of hypothermia while performing diving works under low ambient temperatures and helps to prevent occupational diseases, directly or indirectly related to the impact of low ambient temperatures on the body.CONCLUSION: The application of electric heating system for divers significantly reduces the risk of hypothermia while performing diving works under low ambient temperatures, enables to increase allowable time in water in the diving suit 3,5–4,6 times and helps to prevent occupational diseases, directly or indirectly related to the impact of low ambient temperatures on the body.
The article considers development of a model for a case of arc discharge in a gas stream. The authors examine the traditional geometry of arc plasma device in which arc stabilisation is carried out by a shelf.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.