Prominent crista terminalis is a variant of normal heart anatomy mimicking right atrial mass-like tumour, thrombus, or vegetation. The case report depicts a rare kind of this structure that constitutes a thick muscular bridge in the right atrium. Detection by 2D and 3D echocardiography can avoid further useless investigation.
The "EGM width criterion" is a discrimination algorithm that was available in the last generation ICDs. It improved ventricular tachycardia detection by withholding inappropriate therapy deliveries in the presence of narrow QRS tachycardias. The accuracy of the algorithm depends on the optimal settings of the intracardiac EGM source, the "slew thresholds," and the "width threshold." The possible dependence of these parameters on body position may affect the detection efficacy. Whether these effects can be minimized by a proper choice of the electrode configuration used for signal analysis is still to be investigated. This study aimed to evaluate the stability of the slew threshold and width threshold obtained in the supine and orthostatic positions detected by the tip-to-ventricular coil and can-to-ventricular coil electrode configurations. Their time dependence was also evaluated at the 6-month follow-up. Fifty-eight patients who were recipients of an ICD (model Medtronic 7223cx and 7227cx) were included in the study. Changing from supine to orthostatic position caused a marked variation of slew and width thresholds (21.0 +/- 13.9 V/s and 10.1 +/- 9.6 ms, respectively) in 36% of patients with tip-to-ventricular coil and in 44% of patients with can-to-defibrillating coil (the mean slew threshold variation was in this case 17.6 +/- 15.8 V/s, while the mean width threshold variation was 18.8 +/- 21.0 ms). Width threshold variation was statistically significant (P < 0.02) with the latter electrode configuration. Slew thresholds settings changed between the 1- and 6-month follow-ups in the 75% of patients with can-to-defibrillating coil configuration and in 50% with tip-to-defibrillating coil. These time related variations were significantly larger with the tip-to-defibrillating coil configuration (P < 0.01). In conclusion, EGM width parameters may change between supine and orthostatic position and over time with tip-to-defibrillating coil configuration and can-to-defibrillating coil configuration. The former configuration was less sensitive to body position changes, but more sensitive to time related variations. These findings may be useful for optimal programming of the EGM width criterion, but if parameter programming based on these results can improve the discrimination specificity still needs to be investigated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.