Avulsion-type disk herniation seems to be common, and vertebral endplate marrow signal intensity changes on MR images are indicative of cartilaginous material in the extruded disk herniation material.
The objective of this study was to compare the effective radiation dose of perineural and epidural injections of the lumbar spine under computed tomography (CT) or fluoroscopic guidance with respect to dose-reduced protocols. We assessed the radiation dose with an Alderson Rando phantom at the lumbar segment L4/5 using 29 thermoluminescence dosimeters. Based on our clinical experience, 4-10 CT scans and 1-min fluoroscopy are appropriate. Effective doses were calculated for CT for a routine lumbar spine protocol and for maximum dose reduction; as well as for fluoroscopy in a continuous and a pulsed mode (3-15 pulses/s). Effective doses under CT guidance were 1.51 mSv for 4 scans and 3.53 mSv for 10 scans using a standard protocol and 0.22 mSv and 0.43 mSv for the low-dose protocol. In continuous mode, the effective doses ranged from 0.43 to 1.25 mSv for 1-3 min of fluoroscopy. Using 1 min of pulsed fluoroscopy, the effective dose was less than 0.1 mSv for 3 pulses/s. A consequent low-dose CT protocol reduces the effective dose compared to a standard lumbar spine protocol by more than 85%. The latter dose might be expected when applying about 1 min of continuous fluoroscopy for guidance. A pulsed mode further reduces the effective dose of fluoroscopy by 80-90%.
The high negative predictive accuracy in the whole group suggests that the scan can be used to exclude infection in most cases. Negative results with a high clinical suspicion merits further investigation. A positive result will require further correlative imaging, especially for total knee replacement.
1. There are different patterns of signal alterations in the three groups. 2. The importance of the central region of the CEP for the integrity of the disc is strongly supported by the low incidence of signal alterations in this location in non-operated segments. 3. There are clear indications for the influence of the operation on the development and distribution of signal alterations. 4. In pre-operated segments signal alterations occurring in the central and ventral mid-sagittal regions of the upper CEP can be indicative of the development of RLDH.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.