This laboratory study tested new methods to analyze hemostasis alterations in septic patients. Samples of ethylenediamine tetraacetic acid (EDTA) plasma and citrated plasma were collected from 62 patients with clinical diagnosis of sepsis. Additionally, a subset of EDTA-plasma samples from each patient was stabilized 1 + 1 with 2.5 mol/l arginine, pH 8.6, to conserve the real hemostasis activation state. EDTA-arginine plasma, EDTA plasma and citrated plasma samples were tested in duplicate. The patients at admission to the intensive care unit had 36 +/- 26 (normal, 0.8 +/- 0.2) ng/ml global endotoxin reactivity, 188 +/- 66% (normal, 100 +/- 20%) fibrinogen function, 179 +/- 66% (normal, 100 +/- 20%) fibrinogen antigen, 4.0 +/- 3.6 (normal, 0.049 +/- 0.025) microg/ml D-dimer, 313 +/- 307% (normal, 100 +/- 30%) plasmin-antiplasmin complex, 8.7 +/- 11.4 (normal, 1.1 +/- 0.7) U/ml plasminogen activator inhibitor-1, 12.1 +/- 10.5 (normal, 1.3 +/- 0.4) ng/ml thrombin-antithrombin III complex, 173 +/- 62% (normal, 100 +/- 20%) thrombin, 568 +/- 225 (normal, 140 +/- 42) pg/ml tissue factor, and 2.56 +/- 2.48 (normal, 0.19 +/- 0.04) microg/ml soluble intercellular adhesion molecule-1. Endotoxin (lipopolysaccharide and/or beta-glucan) reactivity (EDTA plasma), fibrinogen function + antigen + ratio and plasminogen activator inhibitor-1 (citrated plasma), and D-dimer, soluble intercellular adhesion molecule-1, thrombin activity (EDTA-arginine-stabilized plasma) presented large aberrations in septic patients when compared with normal values and may therefore be particularly interesting as markers of hemostasis alteration. Whether the observed alterations are of clinical significance has to be determined in well defined patient groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.