A linear geological structure which is suspected to be a fault within the Precambrian Basement Complex rocks of Ogbomoso, Southwestern Nigeria is found in the geological map of Ogbomoso Southwest Sheet 222. The ground magnetic and electrical resistivity methods were used to investigate the structure and determine its physical characteristics. Five (5) traverses with lengths varying from 700–800 m and trending NNW-SSE (N338oW) were established perpendicularly (ENE-WSW, N68oE) to the suspected fault. Total magnetic field data were acquired at 10 m interval, corrected for diurnal variation and inverted using the Geosoft Oasis Montaj software package. Dipole-Dipole resistivity data were acquired on the traverses using a dipole length of 20 m with expansion factor n varying from 1 to 5 and modelled to generate 2D resistivity structures with the DIPPRO™ software package. Thirty-seven (37) depth sounding data were acquired, quantitatively interpreted and the results used to generate geoelectric sections along the suspected geologic features. Three (3) parallel linear features F1-F1, F2-F2 and F3-F3 characterized by peak negative (-110 to -20 nT) magnetic anomalies typical of thin and thick dykes (in low magnetic latitude) and low resistivity vertical discontinuities (˃ 188 m deep, 30–153 m wide) within 2D resistivity structures, were identified across the five traverses. F1-F1 coincided with the suspected fault, F1-F1. F2-F2 and F3-F3 are parallel and suspected to be syngenetic with F1-F1. The absence of a significant vertical displacement, typical of normal faulting, in the basement bedrock on the 2D geoelectric sections corroborated the inference of strike slip faulting from the geological map.
A linear geological structure which is suspected to be a fault within the Precambrian Basement Complex rocks of Ogbomoso, Southwestern Nigeria is found in the geological map of Ogbomoso Southwest Sheet 222. The ground magnetic and electrical resistivity methods were used to investigate the structure and determine its physical characteristics. Five (5) traverses with lengths varying from 700–800 m and trending NNW-SSE (N338oW) were established perpendicularly (ENE-WSW, N68oE) to the suspected fault. Total magnetic field data were acquired at 10 m interval, corrected for diurnal variation and inverted using the Geosoft Oasis Montaj software package. Dipole-Dipole resistivity data were acquired on the traverses using a dipole length of 20 m with expansion factor n varying from 1 to 5 and modelled to generate 2D resistivity structures with the DIPPRO™ software package. Thirty-seven (37) depth sounding data were acquired, quantitatively interpreted and the results used to generate geoelectric sections along the suspected geologic features. Three (3) parallel linear features F1-F1, F2-F2 and F3-F3 characterized by peak negative (-110 to -20 nT) magnetic anomalies typical of thin and thick dykes (in low magnetic latitude) and low resistivity vertical discontinuities (˃ 188 m deep, 30–153 m wide) within 2D resistivity structures, were identified across the five traverses. F1-F1 coincided with the suspected fault, F1-F1. F2-F2 and F3-F3 are parallel and suspected to be syngenetic with F1-F1. The absence of a significant vertical displacement, typical of normal faulting, in the basement bedrock on the 2D geoelectric sections corroborated the inference of strike slip faulting from the geological map.
Aim: To determine whether non-secretion of ABH blood group antigens was associated with Sickle Cell Anaemia. Materials and Methods: Haemaglutination inhibition test was carried out on saliva samples from 300 individuals; 100 of whom had haemoglobin (Hb) genotype AA, 100 HbAS, 50 HbAC and 50 HbSS. ABO blood grouping was carried out by standard methods and Haemoglobin genotype test was performed by cellulose acetate electrophoresis technique. Results: Eighteen percent (18%) of HbAA, 23% of HbAS, 18% of HbAC and 42% of HbSS individuals were non-secretors of ABH antigens (p = 0.007). Non-secretion of ABH substances was more associated with HbSS persons than HbAA (p = 0.002), HbAS (p = 0.016) and HbAC (p = 0.009) individuals. Conclusion: Non-secretion of ABH blood group substances is associated with Sickle Cell Anaemia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.